Không tìm thấy sản phẩm nào cho ""
External heat rejection and coolant management equipment for hydro-cooled ASIC mining operations. This category includes Lianli radiators, CDUs (Coolant Distribution Units), and the Lianli 28-unit cooling cabinet system designed to support up to 28 hydro-cooled miners in a single integrated infrastructure. Hydro miners generate significant heat that must be dissipated through external radiators or dry coolers. The cooling loop circulates a water-glycol mixture through the miner's heat exchangers, absorbs the thermal load, and transfers it to these external units for rejection. Proper radiator sizing depends on the total wattage of your hydro fleet and the ambient temperature at your facility. Lianli (Dongguan Lian Li Electronics Technology) is a specialist manufacturer of liquid cooling solutions for data centers and mining operations. Contact the team for sizing guidance, pricing, and compatibility with your hydro miner fleet.
Không tìm thấy sản phẩm nào
Thử điều chỉnh bộ lọc hoặc từ khóa tìm kiếm của bạn
Thiết bị đã xác nhận
Mọi đơn vị đều được kiểm tra trước khi gửi hàng
Vận chuyển nhanh
1–3 business day dispatch on in-stock units
Chấp nhận Tiền điện tử
Thanh toán bằng BTC, ETH, USDT và nhiều hơn nữa
Chuyên gia làm mát
Hướng dẫn xác định kích thước hệ thống thủy lực của bạn
A hydro-cooled ASIC mining system is only as effective as its ability to reject heat to the environment. The radiator — also referred to as a dry cooler, external heat exchanger, or CDU radiator — is the final stage of the cooling loop: it takes the heat absorbed from your ASIC miners and transfers it into the surrounding air. Undersizing the radiator is the single most common mistake in DIY hydro setups, and the one most likely to cause premature hardware failure or thermal throttling.
Phạm vi có sẵn
4.5–85 kW
Để phù hợp với bất kỳ kích cỡ hệ thống thủy điện nào
Free Cooling
~0 W
Công suất quạt trong khí hậu lạnh dưới 15°C
Ồn ào so với làm mát bằng không khí
−35 dB
Hydro system vs equivalent air-cooled rack
Triển khai
Trong nhà & Ngoài trời
Gắn tường, để sàn hoặc mái nhà ngoài trời
Trong một vòng tuần hoàn làm mát bằng dịch nước, chất làm mát hấp thụ nhiệt từ các chip trên bảng băm bên trong mỗi máy Antminer Hydro. Nước nóng — bây giờ 10–20°C warmer so với lúc ban đầu — thoát ra qua các khớp nối nhanh phía sau và chảy ngược qua ống phân phối trở lại đến bộ tản nhiệt. Bên trong bộ tản nhiệt, chất làm mát nóng đi qua một mảng các lá kim loại và ống trong khi quạt thổi khí xung quanh qua mảng lá tản nhiệt. Nhiệt được truyền từ chất lỏng sang không khí và bị thổi ra xa khỏi thiết bị.
In cold climates (ambient below ~15°C), the temperature differential between the heated coolant and the outdoor air is large enough that the fans can run at minimal speed — or in true cold climates, at near-zero power — and still achieve adequate heat rejection. This is called "free cooling" and represents one of the most significant economic advantages of hydro mining in northern Europe: effective PUE can approach 1.0 during winter months.
The radiator is sized in kilowatts of cooling capacity at a given ambient temperature. A common oversizing rule is to select a radiator rated at 120% of your total ASIC power draw — for example, a 12 kW radiator for a setup drawing 10 kW total. This headroom accounts for higher ambient temperatures in summer, any flow inefficiencies, and future capacity expansion.
1–2 Antminer Hydro units
Compact wall-mount radiator. Suits small home hydro setup or single-machine testbed. Indoor or sheltered outdoor.
3–4 Antminer Hydro units
Mid-range floor-stand or wall-mount unit. Most popular capacity for small racks of 3–4 machines.
6–10 Antminer Hydro units
Tủ làm mát khô đứng lớn hơn, phù hợp cho triển khai đầy đủ trên giá đơn. Thường được lắp đặt ngoài trời với hỗn hợp glycol.
12–20 thiết bị Antminer Hydro
Rack-integrated CDU radiator or multi-circuit dry cooler. Commercial-grade construction for outdoor permanent installation.
25–30+ thiết bị Antminer Hydro
Industrial rack CDU. Full rack deployment heat rejection. Connects to multi-circuit distribution manifolds.
Hydro radiators serve different roles depending on your system configuration — from standalone single-machine setups to rack-scale CDU infrastructure.
Một máy Antminer Hydro duy nhất tiêu thụ khoảng 5,5 kW. Khi hoạt động độc lập, nó cần một bộ làm mát ngoài có công suất từ 4,5–6 kW được kết nối bằng ống đến các bộ nối nhanh phía sau của nó. Bộ làm mát có thể được gắn trên tường trong cùng một phòng, trong hallway hoặc đi qua một bức tường để ra ngoài trời. Một bơm nhỏ (thường là bơm nội bộ của máy kèm theo một đơn vị bổ sung dòng chảy) tuần hoàn chất làm mát. Đây là hệ thống hydro cấp nhập môn.
Typical radiator size
4.5–6 kW
Một giá khai thác đầy đủ gồm 8–12 máy Antminer Hydro tiêu thụ tổng cộng 44–66 kW. Điều này yêu cầu một bộ làm mát dạng radiator ngoài hoặc bộ làm mát khô trong phạm vi 50–85 kW, thường là để trên sàn hoặc gắn ngoài tòa nhà. Một ống phân phối cung cấp chất làm mát từ vòng lặp radiator đến từng bộ kết nối nhanh của máy; ống thu hồi thu thập nước nóng trở lại. Đây là cấu hình hydro tiêu chuẩn cho quy mô giá.
Typical radiator size
50–85 kW
Some enclosed rack cabinets are designed for hydro-compatible ASIC miners and include an integrated radiator inside the cabinet enclosure, rejecting heat through a rear duct or overhead plenum. This creates a fully enclosed, near-silent hydro mining unit. An external radiator is still required for larger cabinet configurations where the internal heat exchanger cannot handle the full thermal load — particularly for 10+ machine cabinets in warmer ambient conditions.
Typical radiator size
10–30 kW (supplemental)
Browse our radiator range above and filter by cooling capacity. If you are building a complete hydro system and want a confirmed component list — radiator, pump, manifolds, hoses, coolant — contact our team. We supply everything needed for a complete hydro loop and offer free system specification for customers purchasing equipment through us.