Buy Hydro-Cooled ASIC Miners — Liquid-Cooled Hardware for Data Centers

Hydro-cooled miners use closed-loop water cooling instead of fans to remove heat from ASIC chips. The result is lower noise (around 50 dB compared to 75+ dB on air-cooled equivalents), better energy efficiency, higher rack density, and longer hardware lifespan. Hydro-cooled facilities achieve PUE of approximately 1.03, meaning only 3% energy overhead beyond the miners themselves, compared to 20%+ on air-cooled data centers. Hydro miners are designed exclusively for data center and industrial hosting operations. They require 380 to 415V three-phase power, liquid cooling infrastructure, and 8 to 10 L/min coolant flow rates. They are not suitable for home mining and should not be ordered for residential deployment. The MillionMiner catalog covers 68 hydro models including the full Bitmain S23 Hydro lineup (580 TH/s at 9.5 J/TH, 865 TH/s, and 1,160 TH/s on the S23 Hydro 3U), the S21 XP Hyd (473 TH/s at 12 J/TH), and WhatsMiner Hydro variants. The majority mine Bitcoin (SHA-256), with select Scrypt and KHeavyHash hydro options for Dogecoin/Litecoin and Kaspa operations. MillionMiner's US hosting facilities support full hydro infrastructure including plumbing, flow monitoring, and pressure management. For operators building their own setups, Lianli radiators and cooling cabinets are available in the Equipment category.

5.0
sao sao sao sao sao
4.97
sao sao sao sao sao
4.5
sao sao sao sao sao
Buy Hydro-Cooled ASIC Miners — Liquid-Cooled Hardware for Data Centers
honeycomb-grid honeycomb-grid
Filter & Sort

Thiết bị đã xác nhận

Bitmain & Lian Li authorised stock

Hỗ trợ Hệ thống Toàn diện

Miners, coolant, infrastructure & accessories

Chấp nhận Tiền điện tử

Thanh toán bằng BTC, ETH, USDT và nhiều hơn nữa

Expert Support

Cooling system specialists on hand

Hạ tầng làm mát nâng cao

Tản nhiệt bằng chất lỏng & Ngâm immersion: Tương lai của khai thác ASIC mật độ cao

Thời kỳ của các trang trại khai thác mỏ dùng hệ thống làm mát bằng không khí đang nhường chỗ cho hạ tầng làm mát bằng chất lỏng. Khi mật độ công suất của ASIC vượt quá khả năng làm mát hiệu quả của không khí — các máy đào Bitcoin hàng đầu hiện tiêu thụ hơn 3.500W mỗi thiết bị — các hoạt động nghiêm túc đang chuyển sang các hệ thống làm mát bằng nước hydro và ngâm để mang lại chỉ số PUE thấp hơn rõ rệt, mật độ tốc độ băm cao hơn trên mỗi mét vuông, hoạt động gần như im lặng và tuổi thọ phần cứng kéo dài. Chúng tôi cung cấp đầy đủ dòng sản phẩm Antminer Hydro của Bitmain, container khai thác của Lian Li, bể ngâm, CDU, bộ tản nhiệt, máy bơm, chất làm mát, cáp và mọi thành phần cần thiết để xây dựng toàn bộ hạ tầng làm mát bằng chất lỏng từ đầu.

PUE Improvement

~1.03 PUE

vs 1.4–1.6 for typical air-cooled facilities

Noise Reduction

~45 dB

± 75–85 dB cho ASIC làm mát bằng không khí

Lợi ích mật độ

3–5×

More hashrate per m² vs air-cooled racks

Tuổi thọ phần cứng

+30–50%

Tuổi thọ ASIC kéo dài hơn so với làm mát bằng không khí


The Three Cooling Paradigms

Không khí vs Thuỷ lực vs Ngâm immersion: Những gì Thực sự Thay đổi

Every mining operation runs on one of three fundamental cooling approaches. The differences in cost, density, efficiency, and operational complexity are substantial — and choosing the wrong one for your scale is an expensive mistake.

Air Cooling

Standard

Cách tiếp cận truyền thống: ASICs hút khí xung quanh qua vỏ máy bằng quạt có tốc độ quay cao, thải khí nóng ra phía sau. Mỗi ASIC bạn từng thấy đều được trang bị hệ thống này. Không cần hạ tầng bên ngoài ngoài một không gian thông gió và nguồn điện.

Chi phí hạ tầng bổ sung bằng không

Simple setup, any location

Bảo hành tiêu chuẩn và hỗ trợ

75–85 dB — cực kỳ ồn ào

PUE 1.4–1.6 — high cooling overhead

Dust ingestion degrades hardware over time

Mật độ thấp — diện tích sàn lớn cần thiết

Tốt nhất cho

Home miners, small farms under 50 units, first-time operators

Làm mát bằng chất lỏng

Liquid-cooled ASICs

Các thiết bị khai thác Hydro là ASIC được chế tạo đặc biệt, nơi bộ trao đổi nhiệt được làm mát bằng nước thay vì quạt làm mát. Vi chip ASIC tạo ra nhiệt, và nhiệt này truyền vào một vòng nước kín qua một tấm làm lạnh trong. Nước nóng đó tuần hoàn tới một bộ làm mát bên ngoài (CDU) để tỏa nhiệt — hoặc ra không khí xung quanh qua một bộ làm mát khô, hoặc qua tháp làm mát. Quạt bị loại bỏ hoàn toàn hoặc giảm đáng kể.

40–50 dB — near-silent operation

PUE ~1.05–1.10 — very efficient

Hình dạng tiêu chuẩn phù hợp với giá đỡ rack

No chemical coolant — uses standard water

Yêu cầu hạ tầng bên ngoài của CDU / tản nhiệt

Ống, phụ kiện, bơm làm tăng chi phí lắp đặt

Dedicated hydro ASIC hardware required

Tốt nhất cho

Mid-to-large farms, noise-sensitive locations, high-density deployments

Immersion Cooling

Toàn bộ việc ngâm mình

“Hệ thống làm mát ngâm chìm nhấn chìm toàn bộ phần cứng ASIC — bo mạch, chip và tất cả — trực tiếp vào một bể dầu cách điện (dầu kỹ thuật) bên trong một bể kín. Chất lỏng hấp thụ nhiệt trực tiếp từ mọi bề mặt thành phần cùng lúc và tuần hoàn tới bộ trao đổi nhiệt. Không khí không di chuyển, không quạt chạy, không bụi vào. Nguyên lý nhiệt động học tuyệt đối vượt trội hơn bất kỳ phương pháp dựa trên không khí nào.”

PUE ~1.02–1.03 — near-theoretical maximum

Hoạt động với các ASIC làm mát bằng không khí tiêu chuẩn (quạt đã được tháo bỏ)

Highest possible hashrate density per m²

Không có bụi, ăn mòn hoặc suy giảm do độ ẩm

Highest upfront infrastructure investment

Dielectric fluid cost & ongoing management

Việc tiếp cận bảo trì yêu cầu xử lý chất lỏng

Tốt nhất cho

Các hoạt động công nghiệp lớn, các khu vực hạn chế không gian, yêu cầu tối đa hóa hiệu quả


Hydro Cooling Deep Dive

How Hydro-Cooled ASICs Work — and Why They Change the Economics

A hydro-cooled ASIC is a purpose-built machine — not a retrofitted air-cooler. Bitmain's Antminer Hydro series (S19 Hydro, S21 Hydro) ships without axial fans and replaces them with an internal water block directly bonded to the hash board components. Coolant — typically clean water or a corrosion-inhibited water-glycol mix — flows through the internal block, absorbs the chip heat, and exits through quick-connect fittings on the rear panel into your external cooling loop.

Vòng làm mát bên ngoài bao gồm một bơm (tuần hoàn chất làm mát qua hệ thống), bộ phân phối (chia luồng đến nhiều máy), ống mềm với các couplings nhanh tháo lắp (thay máy không cần dụng cụ), và một Đơn vị Phân phối Chất làm Mát (CDU) hoặc bộ tản nhiệt giúp giải phóng nhiệt ra môi trường. Trong khí hậu lạnh, làm mát tự nhiên qua các bộ làm mát khô có thể giảm tiêu thụ năng lượng của toàn bộ hệ thống làm mát gần như bằng không — đạt PUE gần 1.0 trong các tháng mùa đông.

Ưu điểm vận hành quan trọng của hệ thống thủy lực so với hệ thống nhúng là khả năng bảo trì: máy khoan thủy lực nằm trong khung tiêu chuẩn, kết nối với các phụ kiện ống nhanh chóng tháo lắp, và có thể thay thế trong chưa đầy hai phút mà không cần thiết bị xử lý chất lỏng. Bảo trì gần như giống hệt với phần cứng làm mát bằng khí — bạn chỉ cần rút các ống ra thay vì cáp nguồn. Đối với các hoạt động yêu cầu chu kỳ phần cứng thường xuyên hoặc cần giải quyết lỗi nhanh chóng, làm mát thủy lực mang lại sự cân bằng tối ưu giữa hiệu quả và sự đơn giản trong vận hành.

The Hydro Cooling Loop

Cách Nước Chảy Qua Hệ Thống Khai Thác Mỏ Nước

01

Chilled Water Supply

CDU or dry cooler delivers cooled water (typically 30–40°C) to the distribution manifold at the head of the rack.

02

Manifold Distribution

A supply manifold splits flow across all machines in the rack. Each machine connects via quick-disconnect hose fittings — no tools required for connection or removal.

03

Internal Cold Plate

Bên trong mỗi ASIC hydro, nước chảy qua một tấm làm mát lạnh được gắn trực tiếp lên các chip của bảng mạch khai thác. Nhiệt lượng truyền từ chip sang nước. Nước thoát ra nóng hơn lúc vào 10–20°C.

04

Return Manifold Collection

Heated water from all machines collects in the return manifold and flows back to the CDU as a combined warm stream.

05

Loại bỏ nhiệt (CDU / Làm mát khô)

CDU chuyển nhiệt từ vòng khai thác kín sang vòng thoát nhiệt bên ngoài — hoặc là bộ làm mát khô (đơn vị ngoài trời dựa trên quạt) hoặc tháp làm mát cho các nhà máy lớn. Ở vùng khí hậu lạnh, bộ làm mát khô có thể hoạt động với công suất quạt gần bằng không.


Immersion System Anatomy

What's Inside an Immersion Cooling System

Immersion Tank

A sealed stainless steel or fibreglass tank — typically 1,000–3,000L capacity — housing the hardware. Each tank holds 12–48 standard ASICs (fans removed) stacked horizontally in purpose-built frames. The entire interior is filled with dielectric fluid.

Dielectric Fluid

Engineered mineral oil or synthetic dielectric fluid (e.g. Engineered Fluids BitCool, 3M Novec). Electrically non-conductive so safe in contact with live electronics. Thermal conductivity ~4× better than air. Non-flammable. Reusable indefinitely with filtration. Top-up required periodically due to evaporation.

Ống trao đổi nhiệt

A coil of heat-exchange tubing sits submerged in the warm dielectric bath. Clean water circulates through this coil, absorbing heat from the fluid and carrying it out of the tank. The fluid and water never mix — they exchange heat through the coil wall only.

CDU / External Cooling Loop

The heated water from the tank coil flows to an external Coolant Distribution Unit, dry cooler, or cooling tower for final heat rejection to atmosphere. This is structurally identical to the hydro cooling external loop.

Filtration & Monitoring

Lọc liên tục loại bỏ bụi bẩn rắn khỏi chất lỏng cách điện. Các cảm biến theo dõi nhiệt độ, mức độ, và tốc độ dòng chảy của chất lỏng. Phần mềm quản lý theo dõi tải nhiệt của từng bể chứa và cảnh báo những bất thường.

Immersion Cooling Deep Dive

Total Submersion: Why Immersion Cooling Is the Endgame for Large Operations

Làm mát ngập hoàn toàn khác biệt rõ ràng so với mọi phương pháp làm mát khác vì nó loại bỏ ranh giới nhiệt giữa chất làm mát và nguồn nhiệt. Trong làm mát bằng không khí, nhiệt phải truyền từ chip đến bộ tản nhiệt nhiệt, rồi đến các cánh tản nhiệt, và cuối cùng đến không khí di chuyển — nhiều giao diện, mỗi giao diện đều tăng trở nhiệt. Trong làm mát ngập, chất lỏng cách điện tiếp xúc trực tiếp với mọi bề mặt của mọi thành phần. Kết quả là nhiệt độ giao điểm của chip thấp hơn 30–50°C so với các thiết lập làm mát bằng không khí tương đương chạy tải công việc giống nhau.

Lower chip temperatures have compounding operational benefits. ASIC failure rates are directly correlated with thermal cycling and sustained high temperatures — immersion-cooled hardware routinely achieves 5–7 year operational lifespans versus 2–3 years for air-cooled machines in hard-running industrial environments. Many operators run immersion ASICs at conservative clock frequencies to maximise longevity, or overclock aggressively knowing the thermal headroom exists. Both strategies are viable in ways they simply are not with air cooling.

Ưu điểm lớn khác là tính linh hoạt của phần cứng: hầu hết các bể ngâm đơn pha chấp nhận các ASIC làm mát bằng khí tiêu chuẩn với quạt đã được tháo bỏ (các đầu cắm quạt được bridged bằng một resistor). Điều này có nghĩa là bạn không cần phải mua phần cứng ngâm đặc biệt — các Antminer S21, WhatsMiner M60 hoặc KS5 hiện có của bạn có thể đi trực tiếp vào bể với một sửa đổi quạt với chi phí thấp. Đây là một lợi thế hiệu quả vốn đáng kể so với làm mát bằng thủy lực, yêu cầu máy móc đặc biệt dành cho phiên bản thủy khí.


Đối đầu

Hydro vs Immersion: Which Is Right for Your Operation?

Cả hai đều vượt trội một cách rõ rệt so với làm mát bằng không khí. Lựa chọn giữa chúng phụ thuộc vào quy mô, phong cách vận hành và phân bổ vốn.

Xem xét Làm mát bằng chất lỏng Immersion Cooling
PUE ~1.05–1.10 ~1,02–1,03
Chi phí hạ tầng ban đầu Trung bình — CDU, ống mềm, dây phân phối High — tanks, fluid, CDU, filtration
Yêu cầu phần cứng Dedicated hydro ASIC variants ASIC tiêu chuẩn (quạt đã tháo)
Truy cập Bảo trì Giá đỡ tiêu chuẩn — nhanh chóng & sạch sẽ Tank access — fluid handling required
Thời gian thay thế phần cứng < 2 minutes 15–30 minutes (drain or crane)
Nhiệt độ Chip Xuất sắc — thấp hơn không khí 20–30°C Best possible — 30–50°C lower than air
Không gian ép xung Tốt Excellent — most thermal headroom
Tuổi thọ phần cứng +30–40% vs air +50–70% vs air
Scalability phù hợp tốt cho mỗi giá Phù hợp nhất trên mỗi mét vuông diện tích sàn
Noise Level ~40–50 dB ~35–45 dB
Quản lý dịch vụ Nước/glycol — đơn giản Dielectric oil — specialist knowledge
Quy mô lý tưởng 20–500+ đơn vị 100–10.000+ đơn vị

Quy tắc chung: nếu bạn cần thay thế phần cứng thường xuyên và muốn tối thiểu hóa phức tạp trong hoạt động, hệ thống thủy lực là lựa chọn ưu việt. Nếu bạn đang xây dựng một hệ thống cố định quy mô lớn và muốn đạt được PUE thấp nhất và tuổi thọ phần cứng lâu nhất, hệ thống ngâm dầu thắng thế. Nhiều hoạt động chuyên nghiệp sử dụng hệ thống thủy lực cho phần cứng thế hệ mới nhất của họ (nơi có khả năng thay đổi頻繁) và hệ thống ngâm dầu cho các máy cũ hơn chạy chu kỳ khấu hao kéo dài.


What We Stock

Bitmain & Lian Li: Complete Hydro & Immersion Infrastructure

Everything you need to build a complete hydro or immersion cooling system — from the miners themselves to every pipe, pump, and panel.

Bitmain

Antminer Hydro Miners

Purpose-built water-cooled ASICs. Fans replaced by internal cold plate. Quick-connect rear fittings for tool-free installation. Current lineup includes the S19 Hydro (158 TH/s), S21 Hydro (335 TH/s), and KS5 Hydro for Kaspa. Designed to integrate directly with Bitmain's own CDU systems or third-party cooling infrastructure.

S19 Hydro S21 Hydro KS5 Hydro
Bitmain & Lian Li

Mining Containers

Turnkey ISO-standard shipping containers pre-configured for hydro or immersion mining. Lian Li's mining containers integrate cooling infrastructure, power distribution, network switching, and physical security into a single deployable unit. Bitmain's container solutions are designed around their Hydro ASIC series. Available in 20ft and 40ft configurations — capacity 100–400 units per container.

20ft & 40ft Kết nối và sử dụng ngay Trong nhà & ngoài trời
Nhiều thương hiệu

Immersion Tanks

Single-phase dielectric immersion tanks in multiple capacities (12-unit, 24-unit, 48-unit configurations). Stainless steel construction, integrated heat exchanger coil, fluid inlet/outlet connections, and top-loading access covers. Designed for 24/7 continuous operation. Compatible with standard air-cooled ASICs (fan-modified) as well as purpose-built immersion hardware.

12 / 24 / 48 đơn vị Stainless steel
Bitmain & Bên thứ ba

CDUs & Hydro Radiators

Đơn vị phân phối chất làm mát (CDUs) và bộ tản nhiệt làm mát khô cho vòng lặp loại bỏ nhiệt ngoài trời. Dòng CDU của Bitmain được thiết kế để tích hợp trực tiếp với loạt Antminer Hydro, có công suất từ 50kW đến 400kW mỗi đơn vị. Bộ làm mát khô của bên thứ ba và bộ trao đổi nhiệt dạng tấm có sẵn để thiết kế hệ thống tùy chỉnh và cho vòng ngoài làm mát ngâm.

50kW – 400kW Trong nhà & ngoài trời
Các thành phần hệ thống

Pumps & Distribution Manifolds

Circulation pumps for both hydro and immersion primary loops. Sizing from small single-rack pumps (20–50 L/min) to large facility-scale units. Stainless or brass distribution manifolds in 6-way, 12-way, and 24-way configurations for splitting coolant flow across multiple machines or racks. Balancing valves and flow meters available for precise per-machine flow optimisation.

Các lưu lượng khác nhau Stainless & brass
Everything Else

Hoses, Couplings & Accessories

Ốc nối nhanh kiểu đẩy phù hợp với các bộ nối sau của dòng Hydro của Bitmain (tuỳ chọn G1/4", 3/8", 1/2"). Ống làm mát bằng EPDM gia cố ở các chiều dài khác nhau. Dung dịch cách điện (dầu khoáng kỹ thuật một pha và các tuỳ chọn tổng hợp). Hóa chất chống ăn mòn dạng cô đặc cho hệ thống nước-glycol. Ống lọc, bộ kit phân tích chất lỏng, cảm biến nhiệt độ, đồng hồ đo lưu lượng và phần cứng giám sát.

Khớp nối QD Dielectric fluid Monitoring

Cẩn thận

Common Liquid Cooling Mistakes

Liquid cooling systems reward proper planning and punish improvisation. These are the mistakes that cost operators the most.

Undersizing the Cooling Loop for Future Expansion

Sai lầm đắt nhất trong thiết kế hệ thống thủy lực. Các nhà vận hành thường định kích thước bơm, manifold và công suất CDU chính xác cho số máy hiện tại — sau đó thêm các đơn vị và phát hiện hệ thống bị quá nhiệt. Thiết kế vòng chính của bạn cho 150% công suất dự kiến từ ngày đầu tiên. Nâng cấp bơm và công suất CDU bổ sung là khả thi nhưng gây gián đoạn. Các cổng manifold và đường kính ống gần như không thể mở rộng mà không phải xây dựng lại vòng.

Using Tap Water Without Treatment in Hydro Systems

Nước máy không xử lý chứa các khoáng chất hòa tan, clo và chất hữu cơ sinh học sẽ gây tích tụ cặn trên các tấm làm lạnh, ăn mòn tại các mối nối và sự phát triển của vi sinh trong vòng tuần hoàn. Luôn sử dụng nước khử ion với dung dịch ức chế ăn mòn được pha chế đặc biệt dành cho hệ thống làm mát kim loại hỗn hợp (tấm làm lạnh nhôm, fittings đồng, manifold thép không gỉ). Kiểm tra tính chất của vòng tuần hoàn hàng quý. Một tấm làm lạnh bị tắc nghẽn do tích tụ cặn sẽ làm chết một ASIC cũng chắc chắn như một quạt hỏng.

Removing Fans From ASICs Before Confirming Immersion Compatibility

Not every ASIC can be safely immersed. Some machines have thermal paste formulations or capacitor types that degrade in dielectric fluid. Some firmware exhibits fan-fault shutdowns that cannot be disabled. Verify immersion compatibility with your specific hardware model and firmware version before buying a tank. Bitmain publishes immersion compatibility lists — consult them. A standard S21 Pro is confirmed immersion-compatible; other models require verification.

Ignoring Coolant Flow Rate Per Machine in Hydro Systems

Mỗi máy Antminer Hydro có một lưu lượng chất làm mát tối thiểu được quy định (thường là 4–8 lít mỗi phút cho mỗi đơn vị). Việc thiếu dòng chảy đủ qua máy gây quá nhiệt cho tấm lạnh cục bộ ngay cả khi nhiệt độ nước lớn dường như vẫn ổn. Đây là nguyên nhân phổ biến của các lỗi bảng băm bí ẩn trong các hệ thống hydro mà cảm biến nhiệt tổng thể cho thấy tình trạng nhiệt độ khỏe mạnh. Lắp đặt đồng hồ đo lưu lượng tại bộ phân phối và cân bằng dòng chảy của từng máy trong quá trình vận hành.

Assuming Immersion Tanks Are Maintenance-Free

Immersion tanks are low-maintenance but not zero-maintenance. Dielectric fluid absorbs water vapour and particulate contamination over time — fluid viscosity and dielectric constant degrade. Most manufacturers recommend fluid testing every 6–12 months and full fluid replacement every 2–3 years depending on operating conditions. Neglecting this leads to reduced thermal performance, potential corrosion, and in extreme cases fluid becoming slightly conductive. Budget for ongoing fluid management from day one.

Buying Hydro Infrastructure Without Confirming Site Water Supply

Hệ thống làm mát bằng thủy lực đòi hỏi nguồn nước làm đầy đáng tin cậy để bù đắp cho tổn thất bay hơi tại bộ làm mát khô. Các công trình lớn có thể mất hàng trăm lit mỗi ngày do bay hơi trong thời tiết nóng. Xác nhận rằng địa điểm của bạn có nguồn cung cấp nước đầy đủ, chất lượng nước phù hợp và có phép xả nước xả ra ngoài (nếu sử dụng tháp giải nhiệt bay hơi). Đây là một vấn đề lập kế hoạch địa điểm đã gây tổn thất cho các dự án thủy lực sau khi đã lắp đặt cơ sở hạ tầng.


FAQ

Hydro & Immersion Cooling FAQ

Các câu trả lời cho các câu hỏi chúng tôi thường nhận được trước khi các nhà vận hành chuyển sang làm mát bằng chất lỏng.

Hydro cooling replaces traditional fan-based air cooling with a closed-loop water circuit. Coolant flows through internal cold plates inside the ASIC, absorbing heat directly from the chips, then transfers it to an external radiator or CDU for rejection. This delivers dramatically lower noise (~40 dB vs 75-85 dB) and better thermal efficiency.

The S23 Hydro (580 TH/s) delivers nearly double the hashrate of the S21 Hydro (335 TH/s) with improved efficiency. The S23 Hydro costs more upfront but earns faster ROI. The S21 Hydro remains a strong option for smaller deployments. Both ship with free DDP delivery.

Hydro miners operate at approximately 40-50 dB — comparable to a quiet conversation. Air-cooled ASICs produce 75-85 dB. This makes hydro miners suitable for office environments, residential areas and noise-sensitive locations where air-cooled miners are impractical.

A CDU (Coolant Distribution Unit) is the central pump and heat-exchange unit in a hydro cooling loop. It circulates coolant through your miners via manifolds and routes heated coolant to an external dry cooler for heat rejection. You need a CDU when running 3+ hydro miners. Browse our mining equipment for CDU options.

A basic hydro loop requires: hydro miners, manifolds with quick-disconnect fittings, a CDU or pump, a dry cooler/radiator, hoses and deionised water with corrosion inhibitor. Contact our team for a free system design consultation — we specify every component for your deployment size.

Hydro systems need coolant chemistry testing every 3-6 months, visual inspection of fittings for leaks, pump performance checks and annual corrosion inhibitor replenishment. Clean radiator fins seasonally. Well-maintained systems run reliably for years. See our FAQ for detailed maintenance schedules.

Hydro cooling typically improves overall system efficiency by 5-15% versus air-cooled equivalents. The gains come from eliminating fan power consumption and maintaining lower, more stable chip temperatures. Combined with hosting at $0.07/kWh, this significantly improves mining economics.

Hydro cooling systems can achieve PUE (Power Usage Effectiveness) of 1.02-1.05, meaning 98% of electricity goes to actual mining. Air-cooled setups typically achieve PUE of 1.15-1.30. In cold climates with free cooling, hydro PUE can approach 1.01 for extended periods — maximising revenue per kWh.

Small hydro setups (1-3 miners with a radiator) are feasible at home if you have a dedicated 240V circuit, space for the radiator and basic plumbing skills. For larger deployments, professional hosting is more practical. Contact us for help sizing a home hydro system.

Size your radiator at 120-130% of total ASIC power draw. Three Antminer S21 Hydro units at 5.5 kW each = ~16.5 kW heat load, requiring a 20-22 kW radiator. For hot climates (sustained 35C+), increase to 140-150%. Browse our mining equipment for compatible radiators.

Yes — Lian Li mining containers support Bitmain Hydro series integration with pre-run coolant distribution infrastructure and compatible quick-disconnect fittings. Contact our team for specific container-to-miner compatibility confirmation and adaptor requirements.

The Antminer S21 Hydro draws ~5,500W and the S23 Hydro draws ~4,700W. Running 24/7, an S23 Hydro costs approximately $240/month at the MillionMiner hosting rate of $0.07/kWh. Hydro models use less total system power than air-cooled equivalents because they eliminate fan energy consumption.

Yes — all hydro miners ship with free worldwide DDP delivery. No customs duties, no import taxes. We package hydro units with extra protection for the water fittings. In-stock models dispatch within 1-3 business days.

Bitmain Hydro miners carry a 180-day manufacturer warranty under normal operating conditions. CDU and cooling infrastructure typically carry 12-month warranties. For miners with MillionMiner hosting, we handle all warranty claims and on-site repairs. See our FAQ for details.

Yes — our hosting facilities fully support hydro-cooled miners with dedicated hydro infrastructure. Same $0.07/kWh rate, 99.9% uptime and real-time monitoring. Purchase your hydro miner and add hosting in a single order.

Yes — MillionMiner provides B2B bulk pricing with dedicated account managers for large hydro deployments. Contact our B2B team with model, quantity and destination. We offer combined purchase + hosting packages and full system design for fleet orders.

Hydro cooling circulates water through internal cold plates inside purpose-built ASICs (e.g. Antminer Hydro series). Immersion cooling submerges standard air-cooled ASICs in dielectric fluid. Hydro is simpler to maintain; immersion achieves higher density but requires specialised tanks and fluid management.

Yes — Bitmain and Lian Li offer hydro-optimised containers with integrated manifolds, CDUs and dry coolers. This is the most efficient deployment format for 50+ hydro miners. Contact us for container-based hydro system design and pricing.

Hydro systems manage heat effectively up to 40-45C ambient with properly sized dry coolers. In sustained heat, use oversized radiators (140-150% capacity) and water-glycol coolant. PUE will increase slightly but remains far better than air cooling in the same conditions.

Our team specialises in hydro cooling system design and deployment. We offer free consultations for customers building hydro installations. Contact us via WhatsApp, email or phone — or visit our FAQ for instant answers.

Ready to Build Your Liquid Cooling System?

Browse our full range of hydro miners, immersion tanks, containers, CDUs, and accessories above. If you are planning a new hydro or immersion deployment and want help sizing the system correctly, contact our team — we offer free system design consultations for customers building complete installations.