Hydro Mining Radiators & Cooling Systems | Lianli Equipment

External heat rejection and coolant management equipment for hydro-cooled ASIC mining operations. This category includes Lianli radiators, CDUs (Coolant Distribution Units), and the Lianli 28-unit cooling cabinet system designed to support up to 28 hydro-cooled miners in a single integrated infrastructure. Hydro miners generate significant heat that must be dissipated through external radiators or dry coolers. The cooling loop circulates a water-glycol mixture through the miner's heat exchangers, absorbs the thermal load, and transfers it to these external units for rejection. Proper radiator sizing depends on the total wattage of your hydro fleet and the ambient temperature at your facility. Lianli (Dongguan Lian Li Electronics Technology) is a specialist manufacturer of liquid cooling solutions for data centers and mining operations. Contact the team for sizing guidance, pricing, and compatibility with your hydro miner fleet.

5.0
yıldız yıldız yıldız yıldız yıldız
4.97
yıldız yıldız yıldız yıldız yıldız
4.5
yıldız yıldız yıldız yıldız yıldız
Hydro Mining Radiators & Cooling Systems | Lianli Equipment
bal peteği ızgarası bal peteği ızgarası
Filtrele & Sırala

Ürün bulunamadı

Filtrelerinizi veya arama teriminizi ayarlamayı deneyin

Doğrulanmış Ekipman

Gönderimden önce test edilen her bir birim

Hızlı Gemiler

Stoktaki birimlerde 1–3 iş günü içinde gönderim

Kripto Kabul Ediliyor

Ödeyin BTC, ETH, USDT ve daha fazlasıyla

Soğutma Uzmanları

Hidro sisteminizin boyutlandırılmasına yardım edin

Isı Reddedilme Altyapısı

Radyatör: Her Hidro Soğutma Döngüsündeki En Kritik Bileşen

Hidro-soğutmalı bir ASIC madencilik sistemi, ortamdan ısı atma yeteneği kadar etkilidir. Radyatör — kuru soğutucu, dış ısı değiştirici veya CDU radyatör olarak da adlandırılır — soğutma döngüsünün son aşamasıdır: ASIC madencilerinizden emilen ısıyı alır ve çevresindeki havaya aktarır. Radyatörün boyutunun yetersiz olması, kendin yap hidro kurulumlarında en yaygın hatadır ve donanımın erken arızalanmasına veya termal kısıtlama yaşanmasına en çok neden olan hatadır.

Mevcut Aralık

4.5–85 kW

Herhangi bir hidro sistem büyüklüğüyle eşleşmek için

Ücretsiz Soğutma

~0 W

Soğuk iklimlerde, 15°C'nin altında fan gücü

Gürültü mü Yoksa Hava Soğutmalı mı

−35 dB

Hidro sistem ile eşdeğer hava soğutmalı raf

Dağıtım

İç ve Dış Mekan

Duvara montaj, yer standı veya dış çatı


Nasıl Çalışır

Hidro Madencilik Soğutma Döngüsünde Radyatörün Rolü

Bir hidro soğutma döngüsünde, soğutucu her Antminer Hydro makinesinin içinde yer alan hash board çiplerinden ısı emer. Bu ısınmış su — şimdi giriş yaptığından 10–20°C daha sıcak — hızlı bağlantı arka bağlantıları aracılığıyla çıkar ve geri dönüş manifoldu üzerinden radyatöre akış sağlar. Radyatörün içinde, sıcak soğutucu metal kanatlar ve tüpler dizisi boyunca geçerken, fanlar ortamdaki havayı kanatlar dizisi üzerinde çeker. Isı, sıvıdan havaya transfer edilir ve birimden uzaklaştırılır.

Soğuk iklimlerde (çevre sıcaklığı yaklaşık 15°C'nin altında), ısınmış soğutucu ve dış hava arasındaki sıcaklık farkı o kadar büyüktür ki, fanlar minimum hızda çalışabilir — veya gerçek soğuk iklimlerde sıfıra yakın güçte — ve yine de yeterli ısı dağılımını sağlayabilirler. Buna "ücretsiz soğutma" denir ve Kuzey Avrupa'da hidro madenciliğin en önemli ekonomik avantajlarından biri olarak kabul edilir: etkin PUE, kış aylarında 1.0'ya yaklaşabilir.

Radyatör, belirli bir ortam sıcaklığında soğutma kapasitesi kilovat cinsinden boyutlandırılmıştır. Yaygın bir aşırı boyutlandırma kuralı, toplam ASIC güç tüketiminizin %120'sine göre derecelendirilmiş bir radyatör seçmektir — örneğin, toplamda 10 kW çeken bir kurulum için 12 kW'lık bir radyatör. Bu boşluk, yazın daha yüksek ortam sıcaklıklarını, herhangi bir akış verimsizliğini ve gelecekteki kapasite artışını dikkate alır.

Radyatör Boyutlandırma Kılavuzu

Kurulumunuz İçin Doğru Kapasiteyi Seçin

4.5–6 kW

1–2 Antminer Hydro birimi

Kompakt duvar tipi radyatör. Küçük ev hidrolik kurulumuna veya tek makine test alanına uygun. İç mekan veya korunmuş dış mekan.

10–12 kW

3–4 Antminer Hydro birimi

Orta seviye ayaklı veya duvara monte birim. 3-4 makinelik küçük raflar için en popüler kapasite.

20–30 kW

6–10 Antminer Hydro birimi

Daha büyük zemin monteli kuru soğutucu, tek raf tam yerleştirme için uygundur. Genellikle açık havada glikol karışımı ile konuşlandırılır.

40–60 kW

12–20 Antminer Hydro birimi

Rack entegreli CDU radyatörü veya çok devreli kuru soğutucu. Dış mekanda kalıcı kurulum için ticari sınıf inşaat.

85 kW +

25–30+ Antminer Hydro birimi

Endüstriyel raf CDU. Tam raf yerleştirme ısı reddi. Çok devreli dağıtım manifoldlarına bağlanır.


Radyatörlerin Kullanıldığı Yerler

Hidro Radyatörleri İçin Üç Dağıtım Bağlamı

Hidro radyatörler, sistem konfigürasyonunuza bağlı olarak farklı görevler görür — tek makine kurulumu’dan rack ölçeğinde CDU altyapısına kadar.

Bağımsız Hidro ASIC Kurulumları

Bir adet Antminer Hydro makinesi yaklaşık 5.5 kW güç çeker. Bağımsız çalıştırıldığında, hızlı bağlantı arka bağlantılarına hortumla bağlanan 4.5–6 kW dış radyatörüne ihtiyaç duyar. Radyatör, aynı odada, koridorda duvara monte edilebilir veya bir duvar geçirerek dış bir mekâna yönlendirilerek kullanılabilir. Küçük bir pompa (genellikle makinenin kendi iç pompası ve ek bir inline birim) soğutucu sıvıyı dolaştırır. Bu, giriş seviyesi hidro kurulumudur.

Tipik radyatör boyutu

4.5–6 kW

Açık Çerçeve Hidro Raflar

8–12 Antminer Hydro makinesinden oluşan tam bir madencilik rafı toplamda 44–66 kW gücünde tüketim yapar. Bu, genellikle yerden yüksek veya bina dışında montajlı olan, 50–85 kW aralığında bir harici radyatör veya kuru soğutucu gerektirir. Bir besleme manifoldu, radyatör döngüsünden soğutucu sıvıyı her makinenin hızlı bağlantı adaptörüne dağıtır; dönüş manifoldu ise ısıtılmış suyu geri toplar. Bu, standart raf ölçekli hidrolik yapılandırmasıdır.

Tipik radyatör boyutu

50–85 kW

Hidro Uyumlu Raf Kabineleri

Bazı kapalı raf dolapları, hidro uyumlu ASIC madencileri için tasarlanmış olup, dolap muhafazası içinde entegre bir radyatör içerir ve ısıyı arka kanat veya tavanda bulunan bir bölme aracılığıyla atar. Bu, tamamen kapalı, neredeyse sessiz bir hidro madencilik ünitesi oluşturur. İç ısı değiştiricisi tam termal yükü karşılamayan daha büyük dolap konfigürasyonları için hâlâ harici bir radyatör gereklidir — özellikle daha sıcak ortam koşullarında 10'dan fazla makine bulunan dolaplar için.

Tipik radyatör boyutu

10–30 kW (destekleyici)


Sıkça Sorulan Sorular

Hidro Radyatörleri Hakkında Yaygın Sorular

A mining radiator (dry cooler) is an outdoor heat exchanger that rejects heat from a hydro cooling loop into the ambient air. It is the final stage of heat rejection in any hydro-cooled ASIC mining setup — essential for keeping coolant temperatures within operating range.

Start with your total ASIC power draw: three Antminer S21 Hydro at 5.5 kW each = 16.5 kW heat load. Select a radiator rated at 120-130% of that figure (20-22 kW). For hot climates (35C+), increase to 140-150%. Contact us with your miner count and site location for exact sizing.

The CDU circulates coolant through your miners, then routes heated coolant to the radiator for heat rejection. The radiator returns cooled fluid to the CDU, completing the loop. CDU and radiator must be matched for flow rate and thermal capacity. Browse our mining equipment for compatible CDU options.

Bitmain radiators are designed specifically for their Hydro miner ecosystem with guaranteed compatibility. Third-party dry coolers often offer higher capacity and better value at larger scales. Both work with standard hydro fittings. Contact us for recommendations based on your fleet size.

Small radiators (4.5-12 kW) can operate indoors with adequate ventilation — the radiator exhausts hot air into the room. Larger units (20 kW+) should be outdoors or in dedicated mechanical spaces. Outdoor installation requires glycol coolant to prevent freezing in cold conditions.

Radiator noise depends on size and fan speed. Small units (4.5-12 kW) produce 45-55 dB. Large industrial dry coolers (50+ kW) can reach 60-70 dB at full speed. Variable-speed fan controllers reduce noise during cooler ambient conditions. For noise-sensitive sites, contact us for low-noise options.

Clean radiator fins seasonally to remove dust and debris that reduce airflow efficiency. Check fan operation quarterly. Inspect hose connections for leaks. Test coolant chemistry every 3-6 months. Well-maintained radiators operate reliably for 10+ years. See our FAQ for detailed schedules.

Radiators are compatible with any hydro mining system that uses standard water/glycol coolant loops — including all Bitmain Antminer Hydro models. The key is matching thermal capacity (kW rating) and coolant flow rate to your setup. Contact us to confirm compatibility with your specific miners.

Radiator fan power is typically 1-5% of the total mining power draw. A 20 kW radiator may use 200-500W for its fans. Variable-speed controllers reduce consumption in cool weather. This is significantly less than air-cooled ASIC fan power, contributing to hydro cooling's superior PUE.

Yes — all radiators and dry coolers ship with free worldwide DDP delivery. No customs duties or import taxes. We handle all logistics, packaging (with protection for fins and fittings), tracking and insurance.

Yes — we offer custom dry cooler configurations for specific capacity requirements, non-standard mounting arrangements and specialised environments. Contact our team with your thermal load, space constraints and site conditions for a tailored solution.

Yes — volume B2B pricing is available for multi-unit radiator and cooling equipment orders. Contact our B2B team with quantities and specifications. We offer combined radiator + CDU + miner + hosting packages for complete hydro deployments.

For indoor setups where ambient temperature stays above 5C, use deionised water with corrosion inhibitor. For outdoor radiators or cold climates, use water-propylene glycol mix — 30% glycol for protection to -15C, 40% for -25C. We stock both corrosion inhibitor and premixed glycol coolant.

Radiator capacity depends on the temperature differential between coolant and ambient air. In hot weather (35C+), effective capacity drops 20-30%. In cold weather, radiators achieve "free cooling" with minimal fan power. Size your radiator for worst-case summer conditions to ensure year-round performance.

For mission-critical operations with 10+ hydro miners, redundant radiators are recommended. If a single radiator fails, your miners will overheat within minutes. Dual radiators with automatic failover protect your fleet. Contact us for redundant cooling system design.

Mount radiators with unrestricted intake and exhaust clearance — typically 1-2 metres minimum on all sides. Avoid recirculation where hot exhaust air feeds back into the intake. Wall-mounted units should exhaust away from the building. Multiple radiators should be spaced to prevent thermal interference.

Quality dry coolers use copper or aluminium fin-and-tube construction with corrosion-resistant coatings. Stainless steel fittings prevent galvanic corrosion. For coastal or high-humidity environments, specify marine-grade coatings. Proper coolant chemistry (corrosion inhibitor) protects internal loop surfaces.

Well-maintained radiators last 10-15+ years. Fan motors are typically the first component to need replacement (5-8 years). Fins and tubing are durable if coolant chemistry is maintained. Regular cleaning and corrosion inhibitor replenishment extend operational life significantly.

Many modern CDUs include temperature and flow monitoring with remote access. Adding inline temperature sensors and flow meters to your radiator loop provides real-time performance data. For hosted setups, our monitoring dashboard tracks cooling system health continuously.

Our team provides free hydro system design consultations including radiator sizing. Contact us via WhatsApp, email or phone with your miner count, site location and climate. Visit our FAQ for instant answers to cooling questions.

Radyatörünüzün Boyutlandırmasında Yardıma mı ihtiyacınız var?

Yukarıdaki radyatör aralığımızı inceleyin ve soğutma kapasitesine göre filtreleyin. Tam bir hidrolik sistem inşa ediyorsanız ve onaylanmış bir bileşen listesine ihtiyacınız varsa — radyatör, pompa, manifoldlar, hortumlar, soğutucu — ekibimizle iletişime geçin. Tam bir hidrolik döngü için gereken her şeyi tedarik ediyoruz ve bizimle ekipman satın alan müşterilere ücretsiz sistem özelliklendirmesi sunuyoruz.