External heat rejection and coolant management equipment for hydro-cooled ASIC mining operations. This category includes Lianli radiators, CDUs (Coolant Distribution Units), and the Lianli 28-unit cooling cabinet system designed to support up to 28 hydro-cooled miners in a single integrated infrastructure. Hydro miners generate significant heat that must be dissipated through external radiators or dry coolers. The cooling loop circulates a water-glycol mixture through the miner's heat exchangers, absorbs the thermal load, and transfers it to these external units for rejection. Proper radiator sizing depends on the total wattage of your hydro fleet and the ambient temperature at your facility. Lianli (Dongguan Lian Li Electronics Technology) is a specialist manufacturer of liquid cooling solutions for data centers and mining operations. Contact the team for sizing guidance, pricing, and compatibility with your hydro miner fleet.

5.0
ster ster ster ster ster
4.97
ster ster ster ster ster
4.5
ster ster ster ster ster
Hydro Mining Radiators & Cooling Systems | Lianli Equipment
bijenkorf-raster bijenkorf-raster
Filteren & Sorteren

Geen producten gevonden

Probeer je filters of zoekterm aan te passen

Geverifieerde apparatuur

Elke eenheid getest vóór verzending

Verzenden snel

Verzendingsduur van 1–3 werkdagen voor voorraden

Crypto geaccepteerd

Betaal met BTC, ETH, USDT & meer

Koeltechniek Experts

Help bij het bepalen van de juiste maat voor je hydro systeem

Warmteafvoerinfrastructuur

De radiator: het belangrijkste onderdeel in elke hydrokoelingslus

Een hydro-gekoelde ASIC-miningsysteem is slechts zo effectief als zijn vermogen om warmte aan de omgeving af te voeren. De radiator — ook wel een droogkoeler, extern warmtewisselaar of CDU-radiator genoemd — is de laatste fase van de koelingslus: hij neemt de warmte op die door je ASIC-miners wordt geabsorbeerd en geeft deze af aan de omgevingslucht. Het te klein maken van de radiator is de meest voorkomende fout bij doe-het-zelf hydro-opstellingen, en de fout die het meest waarschijnlijk vroegtijdige hardwarestoringen of thermal throttling veroorzaakt.

Beschikbare bereik

4.5–85 kW

Om elke hydro systeemgrootte te matchen

Gratis Koeling

~0 W

Ventilatorkracht in koude klimaten onder 15°C

Geluidoverlast versus Luchtgekoeld

−35 dB

Hydro-systeem versus equivalent luchtgekoelde rack

Implementatie

Binnen & Buiten

Muurbevestiging, vloerstandaard of buitendak


Hoe het werkt

De rol van de radiator in een hydro mining koelingslus

In een hydro koelingslus absorbeert koelvloeistof de warmte van de chips op het hashbord binnen elke Antminer Hydro-machine. Dat verwarmde water — nu 10–20°C warmer dan toen het binnenkwam — verlaat het via de snelkoppeling achteraan en stroomt terug door de retourverdeling naar de radiator. Binnenin de radiator passeert de hete koelvloeistof een reeks metalen vinnen en buizen, terwijl ventilatoren de omgevingslucht over de vinnen trekken. De warmte wordt overgedragen van de vloeistof naar de lucht en wordt afgevoerd weg van de eenheid.

In koude klimaten (omgevingstemperatuur onder ~15°C) is het temperatuurverschil tussen de verwarmde koelvloeistof en de buitenlucht groot genoeg dat de ventilatoren op minimale snelheid kunnen draaien — of in echte koude klimaten op bijna nul vermogen — en toch voldoende warmte afvoeren. Dit wordt "gratis koeling" genoemd en is een van de belangrijkste economische voordelen van hydro-mijnbouw in Noord-Europa: een effectieve PUE kan tijdens de wintermaanden bijna 1,0 benaderen.

De radiator is gespecificeerd in kilowatt koelvermogen bij een gegeven omgevingstemperatuur. Een gebruikelijke oversizeerregel is om een radiator te kiezen die is gewaardeerd op 120% van uw totale ASIC-verbruik — bijvoorbeeld een radiator van 12 kW voor een installatie die 10 kW verbruikt. Deze extra marge houdt rekening met hogere omgevingstemperaturen in de zomer, eventuele flow-inefficiënties en toekomstige capaciteitsuitbreidingen.

Gids voor het bepalen van de radiatormaat

Kies de juiste capaciteit voor jouw opstelling

4.5–6 kW

1–2 Antminer Hydro-eenheden

Compact wandradiator. geschikt voor kleine woninghydrosysteem of enkele testopstelling. Geschikt voor binnen of beschut buitengebruik.

10–12 kW

3–4 Antminer Hydro-eenheden

Mid-range vloerstaande of muurbevestigde eenheid. Meest populaire capaciteit voor kleine racks van 3–4 machines.

20–30 kW

6–10 Antminer Hydro-eenheden

Grotere vloerstaande droge koeler, geschikt voor volledige inzet op één rek. Wordt vaak buiten gebruikt met glycolmengsel.

40–60 kW

12–20 Antminer Hydro-eenheden

Rack-geïntegreerde CDU-radiator of multi-circuit droge koeler. Commerciële kwaliteit constructie voor permanente buiteninstallatie.

85 kW +

25–30+ Antminer Hydro-eenheden

Industriële rek CDU. Volledige rek-implementatie warmteafvoer. Verbonden met multicircuit distributiemanifolds.


Waar Radiatoren Worden Gebruikt

Drie inzetcontexten voor hydro-radiatoren

Hydro-radiatoren vervullen verschillende rollen, afhankelijk van de configuratie van uw systeem — van standalone enkelvoudige-machine-opstellingen tot rack-grootte CDU-infrastructuur.

Onafhankelijke Hydro ASIC-opstellingen

Een enkele Antminer Hydro-machine verbruikt ongeveer 5,5 kW. Wanneer hij standalone wordt gebruikt, heeft hij een externe radiator van 4,5–6 kW nodig, verbonden via een slang met de snelkoppelingen aan de achterzijde. De radiator kan aan de muur worden gemonteerd in dezelfde kamer, in een gang of door een muur worden geleid naar een buitenlocatie. Een kleine pomp (vaak de interne pomp van de machine zelf plus een aanvullende inline-unit) circuleert het koelmiddel. Dit is de instap-Hydro-opstelling.

Typische radiatorgrootte

4,5–6 kW

Open-Frame Hydro Rekken

Een volledige mijnbouwrack met 8–12 Antminer Hydro-machines verbruikt in totaal 44–66 kW. Dit vereist een externe radiator of droge koeler in de range van 50–85 kW, meestal staand op de vloer of buiten het gebouw gemonteerd. Een toevoercollector verdeelt koelmiddel van de radiatorlus naar de snelkoppelingsaansluiting van elke machine; de retourcollecteur verzamelt het verwarmde water terug. Dit is de standaard rack-schaal hydro-configuratie.

Typische radiatorgrootte

50–85 kW

Hydro-Compatibele Rekenkasten

Sommige afgesloten rekbekkens zijn ontworpen voor hydro-compatibele ASIC-miners en bevatten een geïntegreerde radiator binnen de behuizing, die de warmte afvoert via een achterduct of bovenschoter. Dit creëert een volledig afgesloten, bijna geruisloze hydro-mijnbouwunit. Een externe radiator is nog steeds vereist voor grotere kastconfiguraties waar de interne warmtewisselaar het volledige thermische vermogen niet aankan — vooral bij meer dan 10 machines in warmere omgevingsomstandigheden.

Typische radiatorgrootte

10–30 kW (aanvullend)


Veelgestelde vragen

Veelgestelde vragen over hydroradiatoren

A mining radiator (dry cooler) is an outdoor heat exchanger that rejects heat from a hydro cooling loop into the ambient air. It is the final stage of heat rejection in any hydro-cooled ASIC mining setup — essential for keeping coolant temperatures within operating range.

Start with your total ASIC power draw: three Antminer S21 Hydro at 5.5 kW each = 16.5 kW heat load. Select a radiator rated at 120-130% of that figure (20-22 kW). For hot climates (35C+), increase to 140-150%. Contact us with your miner count and site location for exact sizing.

The CDU circulates coolant through your miners, then routes heated coolant to the radiator for heat rejection. The radiator returns cooled fluid to the CDU, completing the loop. CDU and radiator must be matched for flow rate and thermal capacity. Browse our mining equipment for compatible CDU options.

Bitmain radiators are designed specifically for their Hydro miner ecosystem with guaranteed compatibility. Third-party dry coolers often offer higher capacity and better value at larger scales. Both work with standard hydro fittings. Contact us for recommendations based on your fleet size.

Small radiators (4.5-12 kW) can operate indoors with adequate ventilation — the radiator exhausts hot air into the room. Larger units (20 kW+) should be outdoors or in dedicated mechanical spaces. Outdoor installation requires glycol coolant to prevent freezing in cold conditions.

Radiator noise depends on size and fan speed. Small units (4.5-12 kW) produce 45-55 dB. Large industrial dry coolers (50+ kW) can reach 60-70 dB at full speed. Variable-speed fan controllers reduce noise during cooler ambient conditions. For noise-sensitive sites, contact us for low-noise options.

Clean radiator fins seasonally to remove dust and debris that reduce airflow efficiency. Check fan operation quarterly. Inspect hose connections for leaks. Test coolant chemistry every 3-6 months. Well-maintained radiators operate reliably for 10+ years. See our FAQ for detailed schedules.

Radiators are compatible with any hydro mining system that uses standard water/glycol coolant loops — including all Bitmain Antminer Hydro models. The key is matching thermal capacity (kW rating) and coolant flow rate to your setup. Contact us to confirm compatibility with your specific miners.

Radiator fan power is typically 1-5% of the total mining power draw. A 20 kW radiator may use 200-500W for its fans. Variable-speed controllers reduce consumption in cool weather. This is significantly less than air-cooled ASIC fan power, contributing to hydro cooling's superior PUE.

Yes — all radiators and dry coolers ship with free worldwide DDP delivery. No customs duties or import taxes. We handle all logistics, packaging (with protection for fins and fittings), tracking and insurance.

Yes — we offer custom dry cooler configurations for specific capacity requirements, non-standard mounting arrangements and specialised environments. Contact our team with your thermal load, space constraints and site conditions for a tailored solution.

Yes — volume B2B pricing is available for multi-unit radiator and cooling equipment orders. Contact our B2B team with quantities and specifications. We offer combined radiator + CDU + miner + hosting packages for complete hydro deployments.

For indoor setups where ambient temperature stays above 5C, use deionised water with corrosion inhibitor. For outdoor radiators or cold climates, use water-propylene glycol mix — 30% glycol for protection to -15C, 40% for -25C. We stock both corrosion inhibitor and premixed glycol coolant.

Radiator capacity depends on the temperature differential between coolant and ambient air. In hot weather (35C+), effective capacity drops 20-30%. In cold weather, radiators achieve "free cooling" with minimal fan power. Size your radiator for worst-case summer conditions to ensure year-round performance.

For mission-critical operations with 10+ hydro miners, redundant radiators are recommended. If a single radiator fails, your miners will overheat within minutes. Dual radiators with automatic failover protect your fleet. Contact us for redundant cooling system design.

Mount radiators with unrestricted intake and exhaust clearance — typically 1-2 metres minimum on all sides. Avoid recirculation where hot exhaust air feeds back into the intake. Wall-mounted units should exhaust away from the building. Multiple radiators should be spaced to prevent thermal interference.

Quality dry coolers use copper or aluminium fin-and-tube construction with corrosion-resistant coatings. Stainless steel fittings prevent galvanic corrosion. For coastal or high-humidity environments, specify marine-grade coatings. Proper coolant chemistry (corrosion inhibitor) protects internal loop surfaces.

Well-maintained radiators last 10-15+ years. Fan motors are typically the first component to need replacement (5-8 years). Fins and tubing are durable if coolant chemistry is maintained. Regular cleaning and corrosion inhibitor replenishment extend operational life significantly.

Many modern CDUs include temperature and flow monitoring with remote access. Adding inline temperature sensors and flow meters to your radiator loop provides real-time performance data. For hosted setups, our monitoring dashboard tracks cooling system health continuously.

Our team provides free hydro system design consultations including radiator sizing. Contact us via WhatsApp, email or phone with your miner count, site location and climate. Visit our FAQ for instant answers to cooling questions.

Hulp nodig bij het bepalen van de juiste maat voor uw radiator?

Bekijk ons assortiment radiatoren hierboven en filter op koelvermogen. Als u een volledig hydraulisch systeem aan het bouwen bent en een bevestigde onderdelenlijst wilt — radiator, pomp, manifolds, slangen, koelvloeistof — neem dan contact op met ons team. Wij leveren alles wat nodig is voor een volledige hydraulische lus en bieden gratis systeemspecificaties voor klanten die bij ons apparatuur kopen.