Hydro Mining Radiators & Cooling Systems | Lianli Equipment

External heat rejection and coolant management equipment for hydro-cooled ASIC mining operations. This category includes Lianli radiators, CDUs (Coolant Distribution Units), and the Lianli 28-unit cooling cabinet system designed to support up to 28 hydro-cooled miners in a single integrated infrastructure. Hydro miners generate significant heat that must be dissipated through external radiators or dry coolers. The cooling loop circulates a water-glycol mixture through the miner's heat exchangers, absorbs the thermal load, and transfers it to these external units for rejection. Proper radiator sizing depends on the total wattage of your hydro fleet and the ambient temperature at your facility. Lianli (Dongguan Lian Li Electronics Technology) is a specialist manufacturer of liquid cooling solutions for data centers and mining operations. Contact the team for sizing guidance, pricing, and compatibility with your hydro miner fleet.

5.0
星 星 星 星 星
4.97
星 星 星 星 星
4.5
星 星 星 星 星
Hydro Mining Radiators & Cooling Systems | Lianli Equipment
ハニカムグリッド ハニカムグリッド
フィルター & 並べ替え

商品が見つかりませんでした

フィルターや検索条件を調整してみてください

承認済みの機器

出荷前にすべてのユニットを検査済み

迅速に発送

在庫有りのユニットは1〜3営業日以内に出荷。

暗号通貨受け入れ

BTC、ETH、USDT などでお支払いください

冷却の専門家

あなたの水力システムのサイズ調整をお手伝いします

熱排出インフラ

ラジエーター:すべてのハイドロ冷却ループにおいて最も重要なコンポーネント

水冷ASICマイニングシステムは、その熱を環境へ排出する能力にのみ依存します。ラジエーター(ドライクーラー、外部熱交換器、またはCDUラジエーターとも呼ばれる)は冷却ループの最後の段階であり、ASICマイナーから吸収した熱を周囲の空気へと移します。ラジエーターのサイズを誤ることは、DIYの水冷システムで最も一般的な誤りであり、ハードウェアの早期故障やサーマルサイクル制限を引き起こす可能性が最も高いです。

利用可能な範囲

4.5–85 kW

任意の水力システムサイズに一致させる

フリークーリング

~0 W

寒冷地(15°C以下)でのファンの電力

ノイズ対エアク cooled

−35 dB

水冷システムと同等の空冷ラック

展開

屋内&屋外

壁掛け、床置き、または屋上屋外


仕組み

ハイドロマイニング冷却ループにおけるラジエーターの役割

ハイドロクーリングループでは、冷却液が各Antminer Hydroマシン内のハッシュボードチップから熱を吸収します。その加熱された水は、入口時より10〜20°C高温になり、クイックコネクトの背面フィッティングを通って排出され、リターンマニホールドを経由してラジエーターへ流れ戻ります。ラジエーター内部では、熱い冷却液が金属のフィンや管の配列を通過し、ファンが周囲の空気をフィン配列に引き寄せて流します。熱は流体から空気へと伝わり、ユニットから排出されます。

寒冷な気候帯(周囲温度約15°C以下)では、加熱された冷却液と屋外空気の温度差が十分に大きいため、ファンは最小限の速度で動作するか、真の寒冷地ではほぼゼロ電力で動作しても、十分な放熱を実現できます。これを「フリークーリング」と呼び、北ヨーロッパにおけるハイドロマイニングの最大の経済的利点の一つです:冬季には効果的なPUEが1.0に近づくことが可能です。

ラジエーターのサイズは、特定の周囲温度における冷却能力(キロワット)で決定されます。一般的な過剰選定のルールは、総ASIC消費電力の120%に評価されたラジエーターを選ぶことです。たとえば、合計10kWのシステムには12kWのラジエーターを使用します。この余裕は、夏の高温時や流量の非効率性、将来的な容量拡張を考慮したものです。

ラジエーターのサイズ選定ガイド

あなたの設定に適した容量を選びましょう

4.5–6 kW

1–2 アントマイナー・ハイドロユニット

コンパクトな壁掛けラジエーター。小規模な家庭用水冷システムや単体試験台に適しています。屋内または屋外の屋 sheltered で使用可能。

10–12 kW

3–4 アントマイナー・ハイドロユニット

中価格帯の床置きまたは壁掛けタイプ。3〜4台の小規模ラックに最も人気の容量。

20–30 kW

6~10 アントマイナー・ハイドロユニット

大型の床置きドライクーラー、シングルラック全展開に適しています。多くの場合、グリコール混合液とともに屋外に配置されます。

40–60 kW

12–20 アントマイナー・ハイドロユニット

ラック一体型CDUラジエーターまたはマルチサーキットドライクーラー。屋外常設設置向けの商用グレードの構造。

85 kW +

25–30+ アントマイナー・ハイドロユニット

工業用ラック CDU。完全なラック展開による熱排出。多回路分配マニホールドに接続。


ラジエーターが使われる場所

ヒュドララジエーターの3つの展開コンテキスト

ハイドロラジエーターは、ご利用のシステム構成に応じてさまざまな役割を果たします。単独の単一マシンセットアップからラックスケールのCDUインフラストラクチャまで。

スタンドアロンのハイドロASICセットアップ

単一のAntminer Hydroマシンは約5.5 kWを消費します。スタンドアロンで稼働させるためには、ホースで接続されたクイックコネクトリアーフィッティングに外付けのラジエーター(4.5~6 kW)が必要です。ラジエーターは同じ部屋の壁に取り付けたり、廊下に設置したり、壁を通して屋外の場所へ設置することもできます。小型のポンプ(しばしば機械自体の内部ポンプと補助のインラインユニットの両方)が冷却液を循環させます。これがエントリーレベルのハイドロセットアップです。

一般的なラジエーターのサイズ

4.5–6 kW

オープンフレーム水力ラック

8〜12台のAntminer Hydroマシンからなる完全なマイニングラックは、合計で44〜66kWの電力を消費します。これには、50〜85kWの範囲内の外部ラジエーターまたはドライクーラーが必要で、通常は床置きまたは建物外に設置されます。供給マニホールドは、ラジエーター循環から各マシンのクイックコネクトフィッティングに冷却水を分配し、リターンマニホールドは加熱された水を回収します。これが標準的なラックスケールのハイドロ構成です。

一般的なラジエーターのサイズ

50–85 kW

ハイドロ対応ラックキャビネット

一部の囲い込みラックキャビネットは、ハイドロ対応のASICマイナー向けに設計されており、キャビネットの enclosure 内に統合されたラジエーターを備えています。熱はリアダクトや天井のプレナムを通じて排出されます。これにより、完全に密閉されたほぼ静音のハイドロマイニングユニットが作られます。内部の熱交換器が全熱負荷を処理できない大きなキャビネット構成(特に暖房環境下での10台以上のマシンキャビネット)では、外部ラジエーターが依然として必要です。

一般的なラジエーターのサイズ

10–30 kW(補助)


よくある質問

水冷ラジエーターに関するよくある質問

A mining radiator (dry cooler) is an outdoor heat exchanger that rejects heat from a hydro cooling loop into the ambient air. It is the final stage of heat rejection in any hydro-cooled ASIC mining setup — essential for keeping coolant temperatures within operating range.

Start with your total ASIC power draw: three Antminer S21 Hydro at 5.5 kW each = 16.5 kW heat load. Select a radiator rated at 120-130% of that figure (20-22 kW). For hot climates (35C+), increase to 140-150%. Contact us with your miner count and site location for exact sizing.

The CDU circulates coolant through your miners, then routes heated coolant to the radiator for heat rejection. The radiator returns cooled fluid to the CDU, completing the loop. CDU and radiator must be matched for flow rate and thermal capacity. Browse our mining equipment for compatible CDU options.

Bitmain radiators are designed specifically for their Hydro miner ecosystem with guaranteed compatibility. Third-party dry coolers often offer higher capacity and better value at larger scales. Both work with standard hydro fittings. Contact us for recommendations based on your fleet size.

Small radiators (4.5-12 kW) can operate indoors with adequate ventilation — the radiator exhausts hot air into the room. Larger units (20 kW+) should be outdoors or in dedicated mechanical spaces. Outdoor installation requires glycol coolant to prevent freezing in cold conditions.

Radiator noise depends on size and fan speed. Small units (4.5-12 kW) produce 45-55 dB. Large industrial dry coolers (50+ kW) can reach 60-70 dB at full speed. Variable-speed fan controllers reduce noise during cooler ambient conditions. For noise-sensitive sites, contact us for low-noise options.

Clean radiator fins seasonally to remove dust and debris that reduce airflow efficiency. Check fan operation quarterly. Inspect hose connections for leaks. Test coolant chemistry every 3-6 months. Well-maintained radiators operate reliably for 10+ years. See our FAQ for detailed schedules.

Radiators are compatible with any hydro mining system that uses standard water/glycol coolant loops — including all Bitmain Antminer Hydro models. The key is matching thermal capacity (kW rating) and coolant flow rate to your setup. Contact us to confirm compatibility with your specific miners.

Radiator fan power is typically 1-5% of the total mining power draw. A 20 kW radiator may use 200-500W for its fans. Variable-speed controllers reduce consumption in cool weather. This is significantly less than air-cooled ASIC fan power, contributing to hydro cooling's superior PUE.

Yes — all radiators and dry coolers ship with free worldwide DDP delivery. No customs duties or import taxes. We handle all logistics, packaging (with protection for fins and fittings), tracking and insurance.

Yes — we offer custom dry cooler configurations for specific capacity requirements, non-standard mounting arrangements and specialised environments. Contact our team with your thermal load, space constraints and site conditions for a tailored solution.

Yes — volume B2B pricing is available for multi-unit radiator and cooling equipment orders. Contact our B2B team with quantities and specifications. We offer combined radiator + CDU + miner + hosting packages for complete hydro deployments.

For indoor setups where ambient temperature stays above 5C, use deionised water with corrosion inhibitor. For outdoor radiators or cold climates, use water-propylene glycol mix — 30% glycol for protection to -15C, 40% for -25C. We stock both corrosion inhibitor and premixed glycol coolant.

Radiator capacity depends on the temperature differential between coolant and ambient air. In hot weather (35C+), effective capacity drops 20-30%. In cold weather, radiators achieve "free cooling" with minimal fan power. Size your radiator for worst-case summer conditions to ensure year-round performance.

For mission-critical operations with 10+ hydro miners, redundant radiators are recommended. If a single radiator fails, your miners will overheat within minutes. Dual radiators with automatic failover protect your fleet. Contact us for redundant cooling system design.

Mount radiators with unrestricted intake and exhaust clearance — typically 1-2 metres minimum on all sides. Avoid recirculation where hot exhaust air feeds back into the intake. Wall-mounted units should exhaust away from the building. Multiple radiators should be spaced to prevent thermal interference.

Quality dry coolers use copper or aluminium fin-and-tube construction with corrosion-resistant coatings. Stainless steel fittings prevent galvanic corrosion. For coastal or high-humidity environments, specify marine-grade coatings. Proper coolant chemistry (corrosion inhibitor) protects internal loop surfaces.

Well-maintained radiators last 10-15+ years. Fan motors are typically the first component to need replacement (5-8 years). Fins and tubing are durable if coolant chemistry is maintained. Regular cleaning and corrosion inhibitor replenishment extend operational life significantly.

Many modern CDUs include temperature and flow monitoring with remote access. Adding inline temperature sensors and flow meters to your radiator loop provides real-time performance data. For hosted setups, our monitoring dashboard tracks cooling system health continuously.

Our team provides free hydro system design consultations including radiator sizing. Contact us via WhatsApp, email or phone with your miner count, site location and climate. Visit our FAQ for instant answers to cooling questions.

ラジエーターのサイズ選びにお困りですか?

上記のラジエーターラインナップを閲覧し、冷却能力でフィルターしてください。完全なハイドロシステムを構築しており、確定した部品リスト(ラジエーター、ポンプ、マニホールド、ホース、冷却水)を希望される場合は、弊社チームにお問い合わせください。私たちは、完全なハイドロループに必要なすべてを提供し、弊社を通じて機器を購入されたお客様には無料のシステム仕様書もご提供しています。