Hydro Mining Radiators & Cooling Systems | Lianli Equipment

External heat rejection and coolant management equipment for hydro-cooled ASIC mining operations. This category includes Lianli radiators, CDUs (Coolant Distribution Units), and the Lianli 28-unit cooling cabinet system designed to support up to 28 hydro-cooled miners in a single integrated infrastructure. Hydro miners generate significant heat that must be dissipated through external radiators or dry coolers. The cooling loop circulates a water-glycol mixture through the miner's heat exchangers, absorbs the thermal load, and transfers it to these external units for rejection. Proper radiator sizing depends on the total wattage of your hydro fleet and the ambient temperature at your facility. Lianli (Dongguan Lian Li Electronics Technology) is a specialist manufacturer of liquid cooling solutions for data centers and mining operations. Contact the team for sizing guidance, pricing, and compatibility with your hydro miner fleet.

5.0
stella stella stella stella stella
4.97
stella stella stella stella stella
4.5
stella stella stella stella stella
Hydro Mining Radiators & Cooling Systems | Lianli Equipment
griglia a nido d'ape griglia a nido d'ape
Filtra e Ordina

Nessun prodotto trovato

Prova a regolare i tuoi filtri o il termine di ricerca

Attrezzatura Verificata

Ogni unità testata prima della spedizione

Spedisce veloce

Spedizione in 1–3 giorni lavorativi per unità disponibili in magazzino

Crypto Accettato

Paga con BTC, ETH, USDT e altro

Esperti di Raffreddamento

Aiuto per dimensionare il tuo sistema idrico

Infrastruttura di Rifiuto del Calore

Il Radiatore: Il Componente Più Critico in Qualsiasi Circuito di Raffreddamento Idraulico

Un sistema di mining ASIC raffreddato ad acqua è efficace solo quanto la sua capacità di rilasciare calore nell'ambiente. Il radiatore — noto anche come dry cooler, scambiatore di calore esterno o radiatore CDU — è l'ultima fase del circuito di raffreddamento: assorbe il calore dai tuoi miner ASIC e lo trasferisce nell'aria circostante. Sottodimensionare il radiatore è l'errore più comune nelle configurazioni idrauliche fai-da-te ed è quello più probabile a causare guasti hardware prematuri o riduzione delle prestazioni termiche.

Gamma disponibile

4.5–85 kW

Per adattarsi a qualsiasi dimensione del sistema idraulico

Raffreddamento Gratuito

~0 W

Potenza della ventola in climi freddi sotto i 15°C

Rumore vs Raffreddato ad Aria

−35 dB

Sistema idrico vs rack aereocondizionato equivalente

Distribuzione

Interno & Esterno

Montaggio a parete, supporto da pavimento o tetto esterno


Come Funziona

Il Ruolo del Radiatore in un Circuito di Raffreddamento per Idrominiera

In un circuito di raffreddamento ad acqua, il refrigerante assorbe calore dai chip della scheda hash all'interno di ogni macchina Antminer Hydro. Quell'acqua riscaldata — ora 10–20°C più calda rispetto a quando è entrata — esce tramite i raccordi posteriori a connessione rapida e scorre di nuovo attraverso il collettore di ritorno verso il radiatore. All'interno del radiatore, il refrigerante caldo passa attraverso una serie di alette e tubi metallici mentre le ventole aspirano aria ambiente attraverso l'array di alette. Il calore si trasferisce dal fluido all'aria ed è espulso lontano dall'unità.

Nei climi freddi (ambiente sotto ~15°C), il differenziale di temperatura tra il refrigerante riscaldato e l'aria esterna è sufficientemente grande da consentire ai ventilatori di funzionare a velocità minima — o in veri climi freddi, a potenza quasi zero — e ottenere comunque un adeguato scambio di calore. Questo è chiamato "raffreddamento gratuito" e rappresenta uno dei vantaggi economici più significativi del mining idrico nel nord Europa: il PUE efficace può avvicinarsi a 1.0 durante i mesi invernali.

Il radiatore è dimensionato in kilowatt di capacità di raffreddamento a una certa temperatura ambiente. Una regola comune per il sovradimensionamento è selezionare un radiatore con una potenza nominale del 120% del tuo consumo totale di potenza ASIC — ad esempio, un radiatore da 12 kW per un sistema che consuma 10 kW in totale. Questo margine tiene conto di temperature ambientali più elevate in estate, di eventuali inefficienze di flusso e di un futuro ampliamento della capacità.

Guida alla dimensione dei radiatori

Scegli la Capacità Giusta per il Tuo Setup

4.5–6 kW

1–2 unità Antminer Hydro

Radiatore a parete compatto. Adatto per piccoli impianti idraulici domestici o banchi di prova per singole macchine. Interno o all'aperto in zona protetta.

10–12 kW

3–4 unità Antminer Hydro

Unità da pavimento di media gamma o da montare a parete. Capacità più popolare per piccoli rack di 3-4 macchine.

20–30 kW

6–10 unità Antminer Hydro

Raffreddatore a secco da pavimento di dimensioni maggiori, adatto per il dispiegamento completo di un singolo rack. Spesso installato all'aperto con una miscela di glicole.

40–60 kW

12–20 unità Antminer Hydro

Radiatore CDU integrato nel rack o raffreddatore secco a più circuiti. Costruzione di qualità commerciale per installazione permanente all'aperto.

85 kW +

25–30+ unità Antminer Hydro

Rack industriale CDU. Rifiuto di calore per distribuzione completa del rack. Si collega a manifold di distribuzione a più circuiti.


Dove vengono utilizzati i radiatori

Tre contesti di distribuzione per radiatori idraulici

I radiatori idraulici svolgono ruoli diversi a seconda della configurazione del tuo sistema, da impianti autonomi a singola macchina a infrastrutture CDU su scala rack.

Impostazioni Hydro ASIC autonome

Una singola macchina Antminer Hydro consuma circa 5,5 kW. Funzionando in modo autonomo, necessita di un radiatore esterno da 4,5–6 kW collegato tramite un tubo ai suoi attacchi posteriori a connessione rapida. Il radiatore può essere montato a parete nella stessa stanza, in un corridoio, o passato attraverso un muro verso una posizione esterna. Una piccola pompa (spesso la pompa interna della macchina più un'unità supplementare in linea) circola il liquido refrigerante. Questo è il setup idraulico di base.

Dimensione tipica del radiatore

4,5–6 kW

Rastrelliere Idrauliche a Telaio Aperto

Un rack di mining completo di 8–12 macchine Antminer Hydro consuma 44–66 kW in totale. Questo richiede un radiatore esterno o un raffreddatore ad aria nella gamma di 50–85 kW, tipicamente a pavimento o montato all'esterno dell'edificio. Un collettore di alimentazione distribuisce il liquido refrigerante dal circuito del radiatore a ciascun attacco a connessione rapida della macchina; il collettore di ritorno raccoglie l'acqua riscaldata. Questa è la configurazione standard del rack idraulico.

Dimensione tipica del radiatore

50–85 kW

Armadi Rack Idro-Compatibili

Alcuni armadi rack chiusi sono progettati per miner ASIC idro-compatibili e includono un radiatore integrato all'interno dell'involucro dell'armadio, che espelle il calore attraverso un condotto posteriore o un plenum superiore. Questo crea un'unità di mining idro completamente chiusa e quasi silenziosa. Un radiatore esterno è comunque necessario per configurazioni di armadi più grandi in cui lo scambiatore di calore interno non può gestire il carico termico completo, in particolare per armadi con più di 10 macchine in condizioni ambientali più calde.

Dimensione tipica del radiatore

10–30 kW (supplementare)


Domande frequenti

Domande comuni sui radiatori idraulici

A mining radiator (dry cooler) is an outdoor heat exchanger that rejects heat from a hydro cooling loop into the ambient air. It is the final stage of heat rejection in any hydro-cooled ASIC mining setup — essential for keeping coolant temperatures within operating range.

Start with your total ASIC power draw: three Antminer S21 Hydro at 5.5 kW each = 16.5 kW heat load. Select a radiator rated at 120-130% of that figure (20-22 kW). For hot climates (35C+), increase to 140-150%. Contact us with your miner count and site location for exact sizing.

The CDU circulates coolant through your miners, then routes heated coolant to the radiator for heat rejection. The radiator returns cooled fluid to the CDU, completing the loop. CDU and radiator must be matched for flow rate and thermal capacity. Browse our mining equipment for compatible CDU options.

Bitmain radiators are designed specifically for their Hydro miner ecosystem with guaranteed compatibility. Third-party dry coolers often offer higher capacity and better value at larger scales. Both work with standard hydro fittings. Contact us for recommendations based on your fleet size.

Small radiators (4.5-12 kW) can operate indoors with adequate ventilation — the radiator exhausts hot air into the room. Larger units (20 kW+) should be outdoors or in dedicated mechanical spaces. Outdoor installation requires glycol coolant to prevent freezing in cold conditions.

Radiator noise depends on size and fan speed. Small units (4.5-12 kW) produce 45-55 dB. Large industrial dry coolers (50+ kW) can reach 60-70 dB at full speed. Variable-speed fan controllers reduce noise during cooler ambient conditions. For noise-sensitive sites, contact us for low-noise options.

Clean radiator fins seasonally to remove dust and debris that reduce airflow efficiency. Check fan operation quarterly. Inspect hose connections for leaks. Test coolant chemistry every 3-6 months. Well-maintained radiators operate reliably for 10+ years. See our FAQ for detailed schedules.

Radiators are compatible with any hydro mining system that uses standard water/glycol coolant loops — including all Bitmain Antminer Hydro models. The key is matching thermal capacity (kW rating) and coolant flow rate to your setup. Contact us to confirm compatibility with your specific miners.

Radiator fan power is typically 1-5% of the total mining power draw. A 20 kW radiator may use 200-500W for its fans. Variable-speed controllers reduce consumption in cool weather. This is significantly less than air-cooled ASIC fan power, contributing to hydro cooling's superior PUE.

Yes — all radiators and dry coolers ship with free worldwide DDP delivery. No customs duties or import taxes. We handle all logistics, packaging (with protection for fins and fittings), tracking and insurance.

Yes — we offer custom dry cooler configurations for specific capacity requirements, non-standard mounting arrangements and specialised environments. Contact our team with your thermal load, space constraints and site conditions for a tailored solution.

Yes — volume B2B pricing is available for multi-unit radiator and cooling equipment orders. Contact our B2B team with quantities and specifications. We offer combined radiator + CDU + miner + hosting packages for complete hydro deployments.

For indoor setups where ambient temperature stays above 5C, use deionised water with corrosion inhibitor. For outdoor radiators or cold climates, use water-propylene glycol mix — 30% glycol for protection to -15C, 40% for -25C. We stock both corrosion inhibitor and premixed glycol coolant.

Radiator capacity depends on the temperature differential between coolant and ambient air. In hot weather (35C+), effective capacity drops 20-30%. In cold weather, radiators achieve "free cooling" with minimal fan power. Size your radiator for worst-case summer conditions to ensure year-round performance.

For mission-critical operations with 10+ hydro miners, redundant radiators are recommended. If a single radiator fails, your miners will overheat within minutes. Dual radiators with automatic failover protect your fleet. Contact us for redundant cooling system design.

Mount radiators with unrestricted intake and exhaust clearance — typically 1-2 metres minimum on all sides. Avoid recirculation where hot exhaust air feeds back into the intake. Wall-mounted units should exhaust away from the building. Multiple radiators should be spaced to prevent thermal interference.

Quality dry coolers use copper or aluminium fin-and-tube construction with corrosion-resistant coatings. Stainless steel fittings prevent galvanic corrosion. For coastal or high-humidity environments, specify marine-grade coatings. Proper coolant chemistry (corrosion inhibitor) protects internal loop surfaces.

Well-maintained radiators last 10-15+ years. Fan motors are typically the first component to need replacement (5-8 years). Fins and tubing are durable if coolant chemistry is maintained. Regular cleaning and corrosion inhibitor replenishment extend operational life significantly.

Many modern CDUs include temperature and flow monitoring with remote access. Adding inline temperature sensors and flow meters to your radiator loop provides real-time performance data. For hosted setups, our monitoring dashboard tracks cooling system health continuously.

Our team provides free hydro system design consultations including radiator sizing. Contact us via WhatsApp, email or phone with your miner count, site location and climate. Visit our FAQ for instant answers to cooling questions.

Hai bisogno di aiuto per dimensionare il tuo radiatore?

Sfoglia la nostra gamma di radiatori sopra e filtra per capacità di raffreddamento. Se stai costruendo un sistema idro completo e desideri un elenco di componenti confermato — radiatore, pompa, collettori, tubi, liquido di raffreddamento — contatta il nostro team. Forniamo tutto il necessario per un circuito idro completo e offriamo specifiche gratuite del sistema per i clienti che acquistano attrezzature tramite noi.