External heat rejection and coolant management equipment for hydro-cooled ASIC mining operations. This category includes Lianli radiators, CDUs (Coolant Distribution Units), and the Lianli 28-unit cooling cabinet system designed to support up to 28 hydro-cooled miners in a single integrated infrastructure. Hydro miners generate significant heat that must be dissipated through external radiators or dry coolers. The cooling loop circulates a water-glycol mixture through the miner's heat exchangers, absorbs the thermal load, and transfers it to these external units for rejection. Proper radiator sizing depends on the total wattage of your hydro fleet and the ambient temperature at your facility. Lianli (Dongguan Lian Li Electronics Technology) is a specialist manufacturer of liquid cooling solutions for data centers and mining operations. Contact the team for sizing guidance, pricing, and compatibility with your hydro miner fleet.

5.0
estrella estrella estrella estrella estrella
4.97
estrella estrella estrella estrella estrella
4.5
estrella estrella estrella estrella estrella
Hydro Mining Radiators & Cooling Systems | Lianli Equipment
rejilla de panal rejilla de panal
Filtrar y Ordenar

No se encontraron productos

Intenta ajustar tus filtros o término de búsqueda

Equipo verificado

Cada unidad probada antes del envío

Envío rápido

Despacho en 1–3 días hábiles en unidades en stock

Cripto Aceptado

Paga con BTC, ETH, USDT y más

Expertos en Refrigeración

Ayuda para dimensionar su sistema hidroeléctrico

Infraestructura de disipación de calor

El Radiador: El Componente Más Crítico en Cualquier Bucle de Enfriamiento Hidro

Un sistema de minería ASIC enfriado por agua es tan efectivo como su capacidad para rechazar el calor al medio ambiente. El radiador —también conocido como enfriador seco, intercambiador de calor externo o radiador CDU— es la etapa final del circuito de enfriamiento: toma el calor absorbido de tus mineros ASIC y lo transfiere al aire circundante. Subdimensionar el radiador es el error más común en configuraciones hidro DIY, y el que más probablemente cause fallos prematuros de hardware o estrangulación térmica.

Gama Disponible

4.5–85 kW

Para coincidir con cualquier tamaño de sistema hidráulico

Enfriamiento gratuito

~0 W

Potencia del ventilador en climas fríos por debajo de 15°C

Ruido vs refrigeración por aire

−35 dB

Sistema de refrigeración por agua vs rack equivalente refrigerado por aire

Despliegue

Interior & Exterior

Montaje en pared, soporte en suelo o en azotea al aire libre


Cómo funciona

El papel del radiador en un ciclo de enfriamiento de minería por agua

En un circuito de refrigeración por agua, el refrigerante absorbe el calor de los chips de las placas hash dentro de cada máquina Antminer Hydro. Esa agua calentada — ahora 10–20°C más caliente que cuando entró — sale por los racores traseros de conexión rápida y fluye de regreso por el colector de retorno hacia el radiador. Dentro del radiador, el refrigerante caliente pasa a través de un conjunto de aletas metálicas y tubos mientras los ventiladores hacen pasar aire ambiente por el conjunto de aletas. El calor se transfiere del fluido al aire y se expulsa al exterior de la unidad.

En climas fríos (temperatura ambiente por debajo de ~15°C), el diferencial de temperatura entre el refrigerante caliente y el aire exterior es lo suficientemente grande como para que los ventiladores funcionen a velocidad mínima —o, en climas realmente fríos, con potencia prácticamente nula— y aun así logren una disipación de calor adecuada. Esto se conoce como "enfriamiento gratuito" y representa una de las ventajas económicas más significativas de la minería hidroeléctrica en el norte de Europa: la PUE efectiva puede acercarse a 1.0 durante los meses de invierno.

El radiador está dimensionado en kilovatios de capacidad de enfriamiento a una temperatura ambiente determinada. Una regla común de sobredimensionamiento es seleccionar un radiador con una capacidad del 120% de la potencia total de tu ASIC — por ejemplo, un radiador de 12 kW para una configuración que consume 10 kW en total. Este margen adicional tiene en cuenta temperaturas ambiente más altas en verano, cualquier ineficiencia en el flujo y futuras expansiones de capacidad.

Guía para el dimensionado de radiadores

Elige la Capacidad Adecuada para Tu Configuración

4.5–6 kW

1–2 unidades Antminer Hydro

Radiador compacto de montaje en pared. Adecuado para un pequeño sistema hidro en casa o un banco de pruebas de una sola máquina. Interior o al aire libre protegido.

10–12 kW

3–4 unidades Antminer Hydro

Unidad de gama media para instalación en suelo o en pared. Capacidad más popular para bastidores pequeños de 3–4 máquinas.

20–30 kW

6–10 unidades Antminer Hydro

Enfriador seco de mayor tamaño para montaje en suelo, adecuado para despliegue completo en un solo bastidor. A menudo se instala en el exterior con una mezcla de glicol.

40–60 kW

12–20 unidades de Antminer Hydro

Radiador CDU integrado en rack o enfriador seco multicircuito. Construcción de grado comercial para instalación permanente en exteriores.

85 kW +

25–30+ unidades Antminer Hydro

CDU para rack industrial. Rechazo térmico para despliegue de rack completo. Se conecta a colectores de distribución multicircuito.


Dónde se usan los radiadores

Tres contextos de despliegue para radiadores hidro

Los radiadores de agua desempeñan distintos papeles según la configuración de su sistema — desde instalaciones independientes de una sola máquina hasta infraestructuras a escala de rack con CDU.

Configuraciones independientes de ASIC Hydro

Una sola máquina Antminer Hydro consume aproximadamente 5.5 kW. Funcionando de forma independiente, necesita un radiador externo de 4.5 a 6 kW conectado a través de una manguera a sus conexiones traseras de acoplamiento rápido. El radiador se puede montar en la pared en la misma habitación, en un pasillo, o pasar a través de una pared a una ubicación exterior. Una pequeña bomba (a menudo la bomba interna de la máquina más una unidad suplementaria en línea) circula el refrigerante. Esta es la configuración hidro de nivel básico.

Tamaño típico del radiador

4,5–6 kW

Racks Hydro de bastidor abierto

Un rack de minería completo de 8 a 12 máquinas Antminer Hydro consume entre 44 y 66 kW en total. Esto requiere un radiador externo o un enfriador seco en el rango de 50 a 85 kW, típicamente de pie en el suelo o montado fuera del edificio. Un colector de suministro distribuye el refrigerante del circuito del radiador a cada conexión rápida de la máquina; el colector de retorno recoge el agua caliente de vuelta. Esta es la configuración estándar de hidro a escala de rack.

Tamaño típico del radiador

50–85 kW

Armarios para rack compatibles con Hydro

Algunos armarios rack cerrados están diseñados para mineros ASIC compatibles con refrigeración por líquido e incluyen un radiador integrado en el interior del armario, expulsando el calor a través de un conducto trasero o un plenum superior. Esto crea una unidad de minería con refrigeración por líquido totalmente cerrada y casi silenciosa. Aún se requiere un radiador externo para configuraciones de armarios más grandes donde el intercambiador de calor interno no puede soportar toda la carga térmica — especialmente para armarios con más de 10 máquinas en condiciones ambientales más cálidas.

Tamaño típico del radiador

10–30 kW (suplementario)


Preguntas Frecuentes

Preguntas Comunes Sobre Radiadores Hidráulicos

A mining radiator (dry cooler) is an outdoor heat exchanger that rejects heat from a hydro cooling loop into the ambient air. It is the final stage of heat rejection in any hydro-cooled ASIC mining setup — essential for keeping coolant temperatures within operating range.

Start with your total ASIC power draw: three Antminer S21 Hydro at 5.5 kW each = 16.5 kW heat load. Select a radiator rated at 120-130% of that figure (20-22 kW). For hot climates (35C+), increase to 140-150%. Contact us with your miner count and site location for exact sizing.

The CDU circulates coolant through your miners, then routes heated coolant to the radiator for heat rejection. The radiator returns cooled fluid to the CDU, completing the loop. CDU and radiator must be matched for flow rate and thermal capacity. Browse our mining equipment for compatible CDU options.

Bitmain radiators are designed specifically for their Hydro miner ecosystem with guaranteed compatibility. Third-party dry coolers often offer higher capacity and better value at larger scales. Both work with standard hydro fittings. Contact us for recommendations based on your fleet size.

Small radiators (4.5-12 kW) can operate indoors with adequate ventilation — the radiator exhausts hot air into the room. Larger units (20 kW+) should be outdoors or in dedicated mechanical spaces. Outdoor installation requires glycol coolant to prevent freezing in cold conditions.

Radiator noise depends on size and fan speed. Small units (4.5-12 kW) produce 45-55 dB. Large industrial dry coolers (50+ kW) can reach 60-70 dB at full speed. Variable-speed fan controllers reduce noise during cooler ambient conditions. For noise-sensitive sites, contact us for low-noise options.

Clean radiator fins seasonally to remove dust and debris that reduce airflow efficiency. Check fan operation quarterly. Inspect hose connections for leaks. Test coolant chemistry every 3-6 months. Well-maintained radiators operate reliably for 10+ years. See our FAQ for detailed schedules.

Radiators are compatible with any hydro mining system that uses standard water/glycol coolant loops — including all Bitmain Antminer Hydro models. The key is matching thermal capacity (kW rating) and coolant flow rate to your setup. Contact us to confirm compatibility with your specific miners.

Radiator fan power is typically 1-5% of the total mining power draw. A 20 kW radiator may use 200-500W for its fans. Variable-speed controllers reduce consumption in cool weather. This is significantly less than air-cooled ASIC fan power, contributing to hydro cooling's superior PUE.

Yes — all radiators and dry coolers ship with free worldwide DDP delivery. No customs duties or import taxes. We handle all logistics, packaging (with protection for fins and fittings), tracking and insurance.

Yes — we offer custom dry cooler configurations for specific capacity requirements, non-standard mounting arrangements and specialised environments. Contact our team with your thermal load, space constraints and site conditions for a tailored solution.

Yes — volume B2B pricing is available for multi-unit radiator and cooling equipment orders. Contact our B2B team with quantities and specifications. We offer combined radiator + CDU + miner + hosting packages for complete hydro deployments.

For indoor setups where ambient temperature stays above 5C, use deionised water with corrosion inhibitor. For outdoor radiators or cold climates, use water-propylene glycol mix — 30% glycol for protection to -15C, 40% for -25C. We stock both corrosion inhibitor and premixed glycol coolant.

Radiator capacity depends on the temperature differential between coolant and ambient air. In hot weather (35C+), effective capacity drops 20-30%. In cold weather, radiators achieve "free cooling" with minimal fan power. Size your radiator for worst-case summer conditions to ensure year-round performance.

For mission-critical operations with 10+ hydro miners, redundant radiators are recommended. If a single radiator fails, your miners will overheat within minutes. Dual radiators with automatic failover protect your fleet. Contact us for redundant cooling system design.

Mount radiators with unrestricted intake and exhaust clearance — typically 1-2 metres minimum on all sides. Avoid recirculation where hot exhaust air feeds back into the intake. Wall-mounted units should exhaust away from the building. Multiple radiators should be spaced to prevent thermal interference.

Quality dry coolers use copper or aluminium fin-and-tube construction with corrosion-resistant coatings. Stainless steel fittings prevent galvanic corrosion. For coastal or high-humidity environments, specify marine-grade coatings. Proper coolant chemistry (corrosion inhibitor) protects internal loop surfaces.

Well-maintained radiators last 10-15+ years. Fan motors are typically the first component to need replacement (5-8 years). Fins and tubing are durable if coolant chemistry is maintained. Regular cleaning and corrosion inhibitor replenishment extend operational life significantly.

Many modern CDUs include temperature and flow monitoring with remote access. Adding inline temperature sensors and flow meters to your radiator loop provides real-time performance data. For hosted setups, our monitoring dashboard tracks cooling system health continuously.

Our team provides free hydro system design consultations including radiator sizing. Contact us via WhatsApp, email or phone with your miner count, site location and climate. Visit our FAQ for instant answers to cooling questions.

¿Necesita ayuda para elegir el tamaño de su radiador?

Explora nuestra gama de radiadores arriba y filtra por capacidad de refrigeración. Si estás construyendo un sistema hidro completo y deseas una lista de componentes confirmada — radiador, bomba, colectores, mangueras, refrigerante — contacta a nuestro equipo. Suministramos todo lo necesario para un circuito hidro completo y ofrecemos especificaciones de sistema gratuitas para clientes que compran equipos a través de nosotros.