Hydro Mining Radiators & Cooling Systems | Lianli Equipment

External heat rejection and coolant management equipment for hydro-cooled ASIC mining operations. This category includes Lianli radiators, CDUs (Coolant Distribution Units), and the Lianli 28-unit cooling cabinet system designed to support up to 28 hydro-cooled miners in a single integrated infrastructure. Hydro miners generate significant heat that must be dissipated through external radiators or dry coolers. The cooling loop circulates a water-glycol mixture through the miner's heat exchangers, absorbs the thermal load, and transfers it to these external units for rejection. Proper radiator sizing depends on the total wattage of your hydro fleet and the ambient temperature at your facility. Lianli (Dongguan Lian Li Electronics Technology) is a specialist manufacturer of liquid cooling solutions for data centers and mining operations. Contact the team for sizing guidance, pricing, and compatibility with your hydro miner fleet.

5.0
hvězda hvězda hvězda hvězda hvězda
4.97
hvězda hvězda hvězda hvězda hvězda
4.5
hvězda hvězda hvězda hvězda hvězda
Hydro Mining Radiators & Cooling Systems | Lianli Equipment
-mřížka medové plástve -mřížka medové plástve
Filtrovat a seřadit

Nebyly nalezeny žádné produkty

Zkuste upravit své filtry nebo vyhledávací výraz

Ověřené vybavení

Každá jednotka testována před odesláním

Rychlé lodě

Odeslání do 1–3 pracovních dní u skladem dostupných kusů

Přijímá se crypto

Plaťte s BTC, ETH, USDT a dalšími

Odborníci na chlazení

Pomoc s velikostí vašeho hydro systému

Infrastruktura pro odvod tepla

Topení: Nejkritičtější součástka v jakékoli hydrochladičové smyčce

Hydro-chlazený ASIC těžební systém je účinný pouze tak dobře, jak dobře dokáže odvádět teplo do okolního prostředí. Chladič — také označovaný jako suchý chladič, externí výměník tepla nebo radiátor CDU — je konečným stupněm chladicí smyčky: přijímá teplo absorbované z vašich ASIC těžařů a přenáší ho do okolního vzduchu. Nesprávný výběr velikosti radiátoru je nejčastější chybou u domácích hydro setupů a je pravděpodobnější, že způsobí předčasné selhání hardware nebo tepelnou throttling.

Dostupný rozsah

4.5–85 kW

Pro odpovídající jakékoli velikosti hydroelektrického systému

Volné chlazení

~0 W

Výkon ventilátoru v chladných podmínkách pod 15 °C

Hluk vs Chlazení vzduchem

−35 dB

Hydro systém vs ekvivalentní vzduchem chlazená skříň

Nasazení

Vnitřní a venkovní

Nástěnný, podlahový nebo venkovní střešní montar


Jak to funguje

Role radiátoru v chladicím okruhu hydro těžby

V hydro chladicí smyčce chladivo absorbuje teplo z čipů hash desky uvnitř každého stroje Antminer Hydro. Tato ohřátá voda — nyní o 10–20°C teplejší než při vstupu — opouští přes rychlospojky na zadní straně a proudí zpět skrze zpětný rozvodný manažer do chladiče. Uvnitř chladiče prochází horké chladivo přes řadu kovových žebrování a trubek, zatímco ventilátory nasávají okolní vzduch přes žebrovanou mřížku. Teplo se přenáší z kapaliny na vzduch a odvádí se pryč od zařízení.

V chladných klimatických podmínkách (okolní teplota pod ~15°C) je teplotní rozdíl mezi ohřívaným chladivem a venkovním vzduchem dostatečně velký, aby větráky mohly běžet při minimální rychlosti — nebo v opravdu studených klimatických podmínkách při téměř nulovém výkonu — a přesto dosahovaly vhodného odvodu tepla. Tomu se říká „volné chlazení“ a představuje jeden z nejvýznamnějších ekonomických výhod hydro těžby v severní Evropě: účinné PUE se může během zimních měsíců přiblížit hodnotě 1,0.

Chladič je dimenzován v kilowattech chladicího výkonu při dané okolní teplotě. Obvyklé pravidlo pro nadměrné dimenzování je zvolit chladič s výkonem 120 % vašeho celkového příkonu ASIC — například 12 kW chladič pro sestavu s celkovým příkonem 10 kW. Tento rezervní prostor počítá s vyššími okolními teplotami v létě, případnými neefektivitami proudění a budoucím rozšířením kapacity.

Průvodce výběrem radiátoru

Vyberte správnou kapacitu pro vaši sestavu

4.5–6 kW

1–2 jednotky Antminer Hydro

Kompaktní stěnový radiátor. Vhodné pro malou domácí hydro soustavu nebo testovací zařízení s jedním strojem. Vnitřní nebo zastíněný venkovní prostor.

10–12 kW

3–4 jednotky Antminer Hydro

Střední patro na podlahu nebo na zeď. Nejčastější kapacita pro malé stojany s 3–4 stroji.

20–30 kW

6–10 jednotek Antminer Hydro

Větší podlahový suchý chladič, vhodný pro plné nasazení na jeden stojan. Často instalován venku s glykolovou směsí.

40–60 kW

12–20 jednotek Antminer Hydro

Chladicí jednotka s integrovaným radiátorem CDU nebo suchý chladič s více okruhy. Konstrukce profesionální třídy pro venkovní trvalou instalaci.

85 kW +

25–30+ jednotek Antminer Hydro

Průmyslový regál CDU. Kompletní nasazení regálu s odvodem tepla. Připojuje se k distribučním rozvodným větvím s více okruhy.


Kde se používají radiátory

Tři kontexty nasazení pro hydro radiátory

Hydro radiátory plní různé role v závislosti na konfiguraci vašeho systému — od samostatných jednozařízení po infrastrukturu CDU na úrovni racku.

Samostatné uspořádání Hydro ASIC

Jednoduchá funkce Antminer Hydro spotřebuje přibližně 5,5 kW. Při samostatném provozu potřebuje externí chladič o výkonu 4,5–6 kW připojený hadicemi k rychle připojitelným zadním přírubám. Chladič může být namontován na stěnu ve stejném místnosti, v chodbě nebo procházet zdí na venkovní místo. Malá čerpadlo (často vlastní vnitřní čerpadlo stroje plus doplňková přímá jednotka) cirkuluje chladicí kapalinu. Jedná se o základní hydro konfiguraci.

Typická velikost chladiče

4,5–6 kW

Otevřená rámová hydroregály

Plná těžební skříň s 8–12 stroji Antminer Hydro odebírá celkem 44–66 kW. To vyžaduje externí radiátor nebo suchý chladič v rozsahu 50–85 kW, obvykle stojící na podlaze nebo namontovaný mimo budovu. Zásobovací sběrač rozvádí chladicí kapalinu z okruhu radiátoru ke každému rychlospojkovému připojení stroje; zpětný sběrač sbírá ohřátou vodu zpět. Toto je standardní konfigurace hydro skříně na úrovni racku.

Typická velikost chladiče

50–85 kW

Hydro-kompatibilní stojanyové skříně

Některé uzavřené skříně na racky jsou navrženy pro hydro-kompatibilní ASIC těžaře a obsahují integrovaný chladič uvnitř skříně, který odvádí teplo přes zadní ventilaci nebo stropní rozvodku. Tím vzniká plně uzavřená, téměř tichá hydro těžební jednotka. Větší konfigurace skříní, u nichž interní výměník tepla nemůže zvládnout celkovou tepelnou zátěž, stále vyžadují externí chladič — zejména u skříní s více než 10 zařízeními v teplejším okolním prostředí.

Typická velikost chladiče

10–30 kW (doplnkový)


Často kladené dotazy

Obecné otázky o hydroradiátorech

A mining radiator (dry cooler) is an outdoor heat exchanger that rejects heat from a hydro cooling loop into the ambient air. It is the final stage of heat rejection in any hydro-cooled ASIC mining setup — essential for keeping coolant temperatures within operating range.

Start with your total ASIC power draw: three Antminer S21 Hydro at 5.5 kW each = 16.5 kW heat load. Select a radiator rated at 120-130% of that figure (20-22 kW). For hot climates (35C+), increase to 140-150%. Contact us with your miner count and site location for exact sizing.

The CDU circulates coolant through your miners, then routes heated coolant to the radiator for heat rejection. The radiator returns cooled fluid to the CDU, completing the loop. CDU and radiator must be matched for flow rate and thermal capacity. Browse our mining equipment for compatible CDU options.

Bitmain radiators are designed specifically for their Hydro miner ecosystem with guaranteed compatibility. Third-party dry coolers often offer higher capacity and better value at larger scales. Both work with standard hydro fittings. Contact us for recommendations based on your fleet size.

Small radiators (4.5-12 kW) can operate indoors with adequate ventilation — the radiator exhausts hot air into the room. Larger units (20 kW+) should be outdoors or in dedicated mechanical spaces. Outdoor installation requires glycol coolant to prevent freezing in cold conditions.

Radiator noise depends on size and fan speed. Small units (4.5-12 kW) produce 45-55 dB. Large industrial dry coolers (50+ kW) can reach 60-70 dB at full speed. Variable-speed fan controllers reduce noise during cooler ambient conditions. For noise-sensitive sites, contact us for low-noise options.

Clean radiator fins seasonally to remove dust and debris that reduce airflow efficiency. Check fan operation quarterly. Inspect hose connections for leaks. Test coolant chemistry every 3-6 months. Well-maintained radiators operate reliably for 10+ years. See our FAQ for detailed schedules.

Radiators are compatible with any hydro mining system that uses standard water/glycol coolant loops — including all Bitmain Antminer Hydro models. The key is matching thermal capacity (kW rating) and coolant flow rate to your setup. Contact us to confirm compatibility with your specific miners.

Radiator fan power is typically 1-5% of the total mining power draw. A 20 kW radiator may use 200-500W for its fans. Variable-speed controllers reduce consumption in cool weather. This is significantly less than air-cooled ASIC fan power, contributing to hydro cooling's superior PUE.

Yes — all radiators and dry coolers ship with free worldwide DDP delivery. No customs duties or import taxes. We handle all logistics, packaging (with protection for fins and fittings), tracking and insurance.

Yes — we offer custom dry cooler configurations for specific capacity requirements, non-standard mounting arrangements and specialised environments. Contact our team with your thermal load, space constraints and site conditions for a tailored solution.

Yes — volume B2B pricing is available for multi-unit radiator and cooling equipment orders. Contact our B2B team with quantities and specifications. We offer combined radiator + CDU + miner + hosting packages for complete hydro deployments.

For indoor setups where ambient temperature stays above 5C, use deionised water with corrosion inhibitor. For outdoor radiators or cold climates, use water-propylene glycol mix — 30% glycol for protection to -15C, 40% for -25C. We stock both corrosion inhibitor and premixed glycol coolant.

Radiator capacity depends on the temperature differential between coolant and ambient air. In hot weather (35C+), effective capacity drops 20-30%. In cold weather, radiators achieve "free cooling" with minimal fan power. Size your radiator for worst-case summer conditions to ensure year-round performance.

For mission-critical operations with 10+ hydro miners, redundant radiators are recommended. If a single radiator fails, your miners will overheat within minutes. Dual radiators with automatic failover protect your fleet. Contact us for redundant cooling system design.

Mount radiators with unrestricted intake and exhaust clearance — typically 1-2 metres minimum on all sides. Avoid recirculation where hot exhaust air feeds back into the intake. Wall-mounted units should exhaust away from the building. Multiple radiators should be spaced to prevent thermal interference.

Quality dry coolers use copper or aluminium fin-and-tube construction with corrosion-resistant coatings. Stainless steel fittings prevent galvanic corrosion. For coastal or high-humidity environments, specify marine-grade coatings. Proper coolant chemistry (corrosion inhibitor) protects internal loop surfaces.

Well-maintained radiators last 10-15+ years. Fan motors are typically the first component to need replacement (5-8 years). Fins and tubing are durable if coolant chemistry is maintained. Regular cleaning and corrosion inhibitor replenishment extend operational life significantly.

Many modern CDUs include temperature and flow monitoring with remote access. Adding inline temperature sensors and flow meters to your radiator loop provides real-time performance data. For hosted setups, our monitoring dashboard tracks cooling system health continuously.

Our team provides free hydro system design consultations including radiator sizing. Contact us via WhatsApp, email or phone with your miner count, site location and climate. Visit our FAQ for instant answers to cooling questions.

Potřebujete pomoci s velikostí vašeho radiátoru?

Prohlédněte si naši řadu radiátorů výše a filtrováním podle chladicí kapacity. Pokud stavíte kompletní hydro systém a chcete potvrzený seznam součástí — radiátor, čerpadlo, manifoldy, hadice, chladicí kapalina — kontaktujte náš tým. Dodáváme vše, co je potřeba pro kompletní hydro okruh, a nabízíme bezplatné specifikace systému pro zákazníky nakupující vybavení u nás.