Hydro Mining Radiators & Cooling Systems | Lianli Equipment

External heat rejection and coolant management equipment for hydro-cooled ASIC mining operations. This category includes Lianli radiators, CDUs (Coolant Distribution Units), and the Lianli 28-unit cooling cabinet system designed to support up to 28 hydro-cooled miners in a single integrated infrastructure. Hydro miners generate significant heat that must be dissipated through external radiators or dry coolers. The cooling loop circulates a water-glycol mixture through the miner's heat exchangers, absorbs the thermal load, and transfers it to these external units for rejection. Proper radiator sizing depends on the total wattage of your hydro fleet and the ambient temperature at your facility. Lianli (Dongguan Lian Li Electronics Technology) is a specialist manufacturer of liquid cooling solutions for data centers and mining operations. Contact the team for sizing guidance, pricing, and compatibility with your hydro miner fleet.

5.0
نجمة نجمة نجمة نجمة نجمة
4.97
نجمة نجمة نجمة نجمة نجمة
4.5
نجمة نجمة نجمة نجمة نجمة
Hydro Mining Radiators & Cooling Systems | Lianli Equipment
شبكة خلايا العسل شبكة خلايا العسل
تصفية وفرز

لم يتم العثور على منتجات

حاول تعديل عوامل التصفية أو عبارة البحث الخاصة بك

معدات موثوقة

كل وحدة تم اختبارها قبل الشحن

سفينة بسرعة

الشحن خلال 1-3 أيام عمل على الوحدات المتوفرة في المخزون

العملات الرقمية مقبولة

ادفع بواسطة BTC، ETH، USDT والمزيد

خبراء التبريد

ساعد في تحديد حجم نظام الهيدرو الخاص بك

بنية تحتية لرفض الحرارة

المُشعِّل: أهم مكون في أي دائرة تبريد مائية

نظام تعدين ASIC المبرد بالماء فقط فعال بقدر قدرته على رفض الحرارة للبيئة. المشع (المبرد) — والمعروف أيضًا بالمبرد الجاف، مبادل الحرارة الخارجي، أو مبرد وحدة التقييم المركزية (CDU) — هو المرحلة النهائية من دائرة التبريد: حيث يأخذ الحرارة الممتصة من معدّنك ASIC وينقلها إلى الهواء المحيط. إن تصغير حجم المشع هو الخطأ الأكثر شيوعًا في أنظمة التبريد المائية اليدوية، والأكثر عرضة للتسبب في فشل الأجهزة المبكر أو الحد من الأداء الحراري.

النطاق المتاح

4.5–85 kW

للمطابقة مع أي حجم لنظام المياه

التبريد المجاني

~0 W

طاقة المروحة في المناخات الباردة أقل من 15°C

ضوضاء مقابل تبريد بالهواء

−35 dB

نظام الهيدرو مقابل رف التبريد الهوائي المكافئ

نشر

داخلي وخارجي

تثبيت على الحائط، أو على الأرض، أو على السطح الخارجي للسطح


كيف تعمل

دور المبرد في دائرة تبريد التعدين المائي

في دائرة تبريد مائي، يمتص سائل التبريد الحرارة من شرائح لوحة التجزئة داخل كل جهاز Antminer Hydro. المياه المسخنة — الآن أدفأ بمقدار 10-20 درجة مئوية مما كانت عليه عند دخولها — تخرج عبر وصلات الاتصال السريع في الخلف وتتدفق مرة أخرى عبر مجمع العودة إلى المبرد. داخل المبرد، يمر سائل التبريد الحار عبر مصفوفة من الأجنحة والأوعية المعدنية بينما تسحب المراوح الهواء المحيط عبر مصفوفة الأجنحة. تنتقل الحرارة من السائل إلى الهواء ويتم طردها بعيدًا عن الوحدة.

في المناطق الباردة (درجة الحرارة المحيطة أقل من ~15°C)، يكون الفرق في درجة الحرارة بين سائل التبريد المسخن والهواء الخارجي كبيرًا بما يكفي لكي تعمل المراوح بسرعة منخفضة — أو في المناخات الباردة جدًا، عند اقتراب من الصفر في القدرة — ومع ذلك تحقق صرفًا مناسبًا للحرارة. يُطلق على هذا اسم "التبريد المجاني" ويمثل أحد أهم المزايا الاقتصادية للتعدين المائي في شمال أوروبا: يمكن أن تقترب كفاءة استهلاك الطاقة الفعالة من 1.0 خلال أشهر الشتاء.

تم تحديد المبرد بقدرة تبريد بالكيلواوات عند درجة حرارة محيط معينة. والقاعدة الشائعة للمبالغة في الحجم هي اختيار مبرد بسعة 120% من إجمالي استهلاك طاقة الـASIC لديك — على سبيل المثال، مبرد بقوة 12 كيلووات لنظام يستهلك إجمالي 10 كيلووات. هذا المجال الاحتياطي يأخذ في الاعتبار درجات حرارة المحيط الأعلى في الصيف، وأي فقدان في تدفق السائل، وتوسعة القدرة المستقبلية.

دليل قياس حجم المبرد

اختر السعة المناسبة لإعدادك

4.5–6 kW

وحدات Antminer Hydro 1–2

مبرد جداري مضغوط. يناسب نظام التدفئة المنزلية الصغيرة أو منصة اختبار جهاز واحد. للاستخدام الداخلي أو الخارجي المغطى.

10–12 kW

3–4 وحدات Antminer Hydro

وحدة ذات قاعدة على الأرض أو تثبيت على الحائط من النطاق المتوسط. السعة الأكثر شعبية للأرفف الصغيرة التي تحتوي على 3-4 آلات.

20–30 kW

6–10 وحدات Antminer Hydro

مبرد جاف أكبر حجماً موزع على الأرض، مناسب لنشر كامل على رف واحد. غالباً ما يُنصب في الهواء الطلق مع خليط الجليكول.

40–60 kW

12–20 وحدات Antminer Hydro

مبرد、 أو مبرد جاف متعدد الدوائر مدمج في الحامل. بناء من نوع تجاري للاستخدام الخارجي الدائم.

85 kW +

25–30+ وحدات Antminer Hydro

رف صناعي CDU. نشر الرف الكامل لطرد الحرارة. يتصل بمحاور توزيع متعددة الدوائر.


أين تُستخدم المبخرات

ثلاث سياقات نشر لمبردات المياه

تخدم المبردات المائية أدوارًا مختلفة اعتمادًا على تكوين نظامك — من إعدادات الجهاز الفردي المستقلة إلى بنية تحتية لوحدة التوزيع المركزية (CDU) على مستوى الرف.

إعدادات وحدات معالجة الأثاريد المستقلة للمياه

تستهلك جهاز أنتمانر هايدرو واحد حوالي 5.5 كيلواط. عند التشغيل المستقل، يحتاج إلى مبرد خارجي بقدرة 4.5–6 كيلواط متصل عبر أنابيب بمنافذ الاتصال السريع في الخلف. يمكن تثبيت المبرد على الحائط في نفس الغرفة، أو في ممر، أو تمريره عبر الحائط إلى موقع خارجي. يدور مضخة صغيرة (غالبًا مضخة داخلية خاصة بالجهاز بالإضافة إلى وحدة تكميلية داخلية) للسائل المبرد. هذه هي إعدادات الهيدرو الأساسية.

حجم المشعاع النموذجي

4.5–6 كيلوواط

رفوف هيدرو ذات إطار مفتوح

يكلف رف التعدين الكامل الذي يتكون من 8–12 جهاز Antminer Hydro ما بين 44–66 كيلووات إجمالاً. يتطلب ذلك مبرد خارجي أو مبرد جاف يتراوح بين 50–85 كيلووات، عادة ما يكون مثبتًا على الأرض أو مركبًا خارج المبنى. يوزع مجمع الإمداد المبرد من دائرة المبرد إلى وصلة التوصيل السريع لكل جهاز؛ ويجمع مجمع العودة الماء المسخن مرة أخرى. هذه هي التكوين القياسي لمقياس رفود الهيدروليكي.

حجم المشعاع النموذجي

50–85 كيلوفوات

خزائن الرفوف المتوافقة مع الهيدرو

تم تصميم بعض خزائن الرفوف المغلقة لتلائم عمال المناجم ASIC القابلين للهواء المائي وتشمل مبردًا داخليًا مدمجًا داخل حاوية الخزانة، حيث ي Reject الحرارة من خلال قناة خلفية أو حيز علوي. هذا يحول الوحدة إلى وحدة تعدين هيدرو مغلقة تمامًا وتقريبًا صامتة. لا يزال من الضروري وجود مبرد خارجي للتركيبات الأكبر من الخزائن حيث لا يمكن لمبادل الحرارة الداخلي التعامل مع العبء الحراري الكامل — وخصوصًا للخزائن التي تحتوي على 10 آلات أو أكثر في ظروف حرارة محيطة أعلى.

حجم المشعاع النموذجي

10–30 كيلوات (تكميلية)


الأسئلة الشائعة

أسئلة شائعة حول مبردات المياه الهيدروليكية

A mining radiator (dry cooler) is an outdoor heat exchanger that rejects heat from a hydro cooling loop into the ambient air. It is the final stage of heat rejection in any hydro-cooled ASIC mining setup — essential for keeping coolant temperatures within operating range.

Start with your total ASIC power draw: three Antminer S21 Hydro at 5.5 kW each = 16.5 kW heat load. Select a radiator rated at 120-130% of that figure (20-22 kW). For hot climates (35C+), increase to 140-150%. Contact us with your miner count and site location for exact sizing.

The CDU circulates coolant through your miners, then routes heated coolant to the radiator for heat rejection. The radiator returns cooled fluid to the CDU, completing the loop. CDU and radiator must be matched for flow rate and thermal capacity. Browse our mining equipment for compatible CDU options.

Bitmain radiators are designed specifically for their Hydro miner ecosystem with guaranteed compatibility. Third-party dry coolers often offer higher capacity and better value at larger scales. Both work with standard hydro fittings. Contact us for recommendations based on your fleet size.

Small radiators (4.5-12 kW) can operate indoors with adequate ventilation — the radiator exhausts hot air into the room. Larger units (20 kW+) should be outdoors or in dedicated mechanical spaces. Outdoor installation requires glycol coolant to prevent freezing in cold conditions.

Radiator noise depends on size and fan speed. Small units (4.5-12 kW) produce 45-55 dB. Large industrial dry coolers (50+ kW) can reach 60-70 dB at full speed. Variable-speed fan controllers reduce noise during cooler ambient conditions. For noise-sensitive sites, contact us for low-noise options.

Clean radiator fins seasonally to remove dust and debris that reduce airflow efficiency. Check fan operation quarterly. Inspect hose connections for leaks. Test coolant chemistry every 3-6 months. Well-maintained radiators operate reliably for 10+ years. See our FAQ for detailed schedules.

Radiators are compatible with any hydro mining system that uses standard water/glycol coolant loops — including all Bitmain Antminer Hydro models. The key is matching thermal capacity (kW rating) and coolant flow rate to your setup. Contact us to confirm compatibility with your specific miners.

Radiator fan power is typically 1-5% of the total mining power draw. A 20 kW radiator may use 200-500W for its fans. Variable-speed controllers reduce consumption in cool weather. This is significantly less than air-cooled ASIC fan power, contributing to hydro cooling's superior PUE.

Yes — all radiators and dry coolers ship with free worldwide DDP delivery. No customs duties or import taxes. We handle all logistics, packaging (with protection for fins and fittings), tracking and insurance.

Yes — we offer custom dry cooler configurations for specific capacity requirements, non-standard mounting arrangements and specialised environments. Contact our team with your thermal load, space constraints and site conditions for a tailored solution.

Yes — volume B2B pricing is available for multi-unit radiator and cooling equipment orders. Contact our B2B team with quantities and specifications. We offer combined radiator + CDU + miner + hosting packages for complete hydro deployments.

For indoor setups where ambient temperature stays above 5C, use deionised water with corrosion inhibitor. For outdoor radiators or cold climates, use water-propylene glycol mix — 30% glycol for protection to -15C, 40% for -25C. We stock both corrosion inhibitor and premixed glycol coolant.

Radiator capacity depends on the temperature differential between coolant and ambient air. In hot weather (35C+), effective capacity drops 20-30%. In cold weather, radiators achieve "free cooling" with minimal fan power. Size your radiator for worst-case summer conditions to ensure year-round performance.

For mission-critical operations with 10+ hydro miners, redundant radiators are recommended. If a single radiator fails, your miners will overheat within minutes. Dual radiators with automatic failover protect your fleet. Contact us for redundant cooling system design.

Mount radiators with unrestricted intake and exhaust clearance — typically 1-2 metres minimum on all sides. Avoid recirculation where hot exhaust air feeds back into the intake. Wall-mounted units should exhaust away from the building. Multiple radiators should be spaced to prevent thermal interference.

Quality dry coolers use copper or aluminium fin-and-tube construction with corrosion-resistant coatings. Stainless steel fittings prevent galvanic corrosion. For coastal or high-humidity environments, specify marine-grade coatings. Proper coolant chemistry (corrosion inhibitor) protects internal loop surfaces.

Well-maintained radiators last 10-15+ years. Fan motors are typically the first component to need replacement (5-8 years). Fins and tubing are durable if coolant chemistry is maintained. Regular cleaning and corrosion inhibitor replenishment extend operational life significantly.

Many modern CDUs include temperature and flow monitoring with remote access. Adding inline temperature sensors and flow meters to your radiator loop provides real-time performance data. For hosted setups, our monitoring dashboard tracks cooling system health continuously.

Our team provides free hydro system design consultations including radiator sizing. Contact us via WhatsApp, email or phone with your miner count, site location and climate. Visit our FAQ for instant answers to cooling questions.

هل تحتاج إلى مساعدة في تحديد حجم المبرد الخاص بك؟

تصفح تشكيلتنا من المشعات أعلاه وفلتر حسب سعة التبريد. إذا كنت تبني نظام تبريد هيدرو كامل وتريد قائمة مكونات مؤكدة — مشعة، مضخة، منافذ، خراطيم، سائل تبريد — اتصل بفريقنا. نحن نوفر كل ما يلزم لنظام هيدرو مكتمل ونقدم خدمة تحديد مواصفات النظام مجانًا للعملاء الذين يشترون معدات من خلالنا.